DN NUMBER HERE
EntraPass Corporate Edition configuration for Integration with Victor
Requirements
- Victor:
- Unified Client and Site Manager v4.4 or higher
- EntraPass Integration (ADVC-ENTRAPASS) V4.4 or higher
- EntraPass:
- EntraPass Corporate Edition v6.01.51 or higher
- SmartLink installed
- Webstation license activated(See Note 1)
- Web Service configured
- EntraPass operator dedicated for EntraPass integration
- Windows Firewall Exception for Inbound Traffic on TCP 8801
Note 1: ONLY one Webstation license is included by default with EntraPass CE. If Victor EntraPass Integration is used, EntraPass Web & GO cannot be used unless additional licenses are purchased.
IMPORTANT:To ensure a successful integration, all EntraPass Components should be installed, configured and operational prior to Victor configuration.
Configuration
- EntraPass:
- Webstation license activation:
From CE Server: General Tab/Registration, On the Left pane, select Webstation and click the “Click here to install component” button (See screenshot below)
From a CE workstation: Options Tab/Registration, activate Webstation (as indicated above)
Note: Once the Webstation license is activated, a Data backup will be performed automatically.
- Web Service Configuration:
From a Workstation: Devices Tab/Applications/SmartLink/SmartLink Web and API Tab - Check Use Web Service
- Set Web Service Protocol to http
- Victor EntraPass Integration Operator:
From a Workstation: System/Operator/New Operator - Login Tab
- Name: Victor Access
- Login name: VictorCE (Must be at least 8 characters)
- Password: victor1 (Case-sensitive, must be at least 7-digit)
- Enable Concurrent logins
- Security Tab
- Login Schedule: Always Valid
- Security Level: Installer
- Workspace: All
- Web parameters
- Enable Allow login
- Enable Concurrent logins
- Default message filter: All Events
See screenshots below:
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450) 444-2029 •
Copyright © 2012 Tyco International Ltd. and its Respective Companies. • All rights reserved.
Specifications are subject to change without prior notice.
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450) 444-2029 •
Copyright © 2012 Tyco International Ltd. and its Respective Companies. • All rights reserved.
Specifications are subject to change without prior notice.
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450) 444-2029 •
Copyright © 2012 Tyco International Ltd. and its Respective Companies. • All rights reserved.
Specifications are subject to change without prior notice.
- Windows Firewall Exception:
If the Windows Firewall is enabled, a rule must be created to allow port TCP 8801 inbound traffic on all 3 profiles (Domain, Private and Public).
Please refer to Windows documentation for instructions.
Once EntraPass configuration is complete, the SmartLink window should look like this:
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450) 444-2029 •
Copyright © 2012 Tyco International Ltd. and its Respective Companies. • All rights reserved.
Specifications are subject to change without prior notice.