DOCUMENTATION HANDED OVER

Goods lift data to be transcribed in the use and maintenance manual:

  • Good lift name______
  • Model:______
  • Serial number:______
  • Year of construction:______

ATTACHMENTS

Declaration of conformity
Obligations of the owner, obligations of the employer,
Good lift manual
User manual
Maintenance manual
Installation manual
Aluminium identification plates

Updinamic S.r.l.

Please return this sheet countersigned as confirmation of receipt of the documents via fax number 0442-599091 or via e-mail to

SIGNATURE FOR RECEIPT(customer)

______

Pagina 1 di 14

DECLARATION OF COMPLIANCE

The company UPDINAMIC S.r.l., which operates in the automatic parking sector, with its registered offices in : via Modigliani, 22 – 37045 – Legnago (VR) -ITALY, entrolled in the records of the Chamber of Commerce of Verona and tax number 03584130235. Enrolled at the EARegister.. 348256

THE LATTER DECLARES UNDER HIS OWN RESPONSIBILITY THAT THE NEW MACHINE

-called ______

-mod, ______

-registration number ______

built during the year ______

Operation mode: apparatus for goods-lifting only, with fixed carrying capacity, connecting the various floors with vertical movement on rigid guides.

start up and complaints to compliant with the needs imposed by the following EC Directives:

  • Machinery Directive 2006/42/CE;
  • CEE 89/106 Directive on construction products;
  • Directive 89/336/CEE

Reference was made to harmonised laws during planning, in particular:

  • standards UNI EN ISO 12100 part I – II; UNI 14010 ; UNI EN ISO 1387:2008 EN 349; EN 60204-1;

It is also declared that::

  • Pursuant to the Machinery Directives 2006/42/CE “the technical file of the machine, together with attachment VII is available at the manufacturer’s site and the updating manager is Mr. Oscar Donà.

It should be noted that the machine cannot be put into service until it is established to comply with all applicable rules and regulations in the country of installation.

Legnago, date ______/______/______,

UPDINAMIC S.r.l.

Via Modigliani 22

Legnago (VR) -Italy

The sole administrator

(Albino Donà)

DECLARATION OF COMPLIANCE

UPDINAMIC s.r.l.

Via Modigliani , 22

37045 LEGNAGO (VR)

GOOD LIFT MANUAL

MODEL UP__

(designed to carry goods only)

INSTALLED IN THE BUILDING OWNED BY:

______IN______N°______

MUNICIPALITY______

MODEL______

SERIAL NO.______

OWNER’S LEGAL REPRESENTATIVE: ______

ANY SUBSEQUENT CHANGES IN SYSTEM OWNERSHIP:

______

THIS MANUAL MUST BE KEPT BY THE OWNER IN THE TECHNICAL CABINET TOGETHER WITH THE ATTACHMENTS LISTED BELOW:

GOOD LIFT MANUAL

USER MANUAL

ELECTRICAL PART MANUAL

MAINTENANCE MANUAL

Pagina 1 di 14

GOOD LIFT MANUAL

Pagina 1 di 14

The good lift has been constructed in compliance with the following directives:

MACHINE DIRECTIVE 2006/42/EC

ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89/336/EEC AND RELATIVE AMENDMENTS

LOW VOLTAGE DIRECTIVE 73/23/EEC

The good lift is hence supplied complete with the documentation as required by these directives.

The good lift has been designed to guarantee safe conditions of use. Deactivating and removing the electrical and other safety devices installed by the manufacturer will seriously jeopardise good lift safety. Proper use moreover requires strictly following the instructions for installation, power supply and maintenance of the good lift.

The good lift must be used according to the intended use specified by the manufacturer in the user manual that accompanies this manual: it is therefore advisable to carefully read this manual before transport, installation and startup of the good lift.

Maintenance consists of a few simple operations that can be carried out by a qualified operator who meets the requirements established by law. In order to get the longest life and the most cost-effective operation out of the good lift, it is advisable to strictly follow the instructions contained in this document and in the accompanying manuals.

The manufacturer cannot be held responsible for breakage, accidents or other problems due to inobservance (or in any case failing to apply) the rules contained in this manual, the user manual and the maintenance manual. The same is true for making modifications, variations or installation of unauthorised accessories.

This manual, the user manual and the maintenance manual form an integral part of the good lift: it is essential that they be kept intact in the technical cabinet of the good lift so that they are easily accessible for the entire lifetime of the goodlift, even in the event of the good lift passing to another user. They must also be easily and readily accessible for consultation by the operators and the maintenance technicians and must therefore be kept close to the equipment.

CAREFULLY READ AND KEEP THIS MANUAL, THE USER MANUAL AND THE MAINTENANCE MANUAL.

SHOULD YOU REQUIRE COPIES OR UPDATES OF THE MANUALS, PLEASE CONTACT:

UPDINAMIC S.r.l. Via Modigliani 22, 37045 Legnago VR (ITALY)

Tel. 0442-590129 – Fax 0442-599091 – E-mail

GOODLIFT DESCRIPTION

Electro-hydraulic vertical goods lift designed for the transportation of goods to various underground or above-ground levels with a travel of up to 12 metres. UP has a wall-mounted load-bearing structure constructed of special structural steel beams in which combined bearings slide. The platform is driven by a hydraulic cylinder with double-chain transmission.

Model / Carrying capacity
Kg
UP 3 / 300
UP 6 / 600
UP 10 / 1000
UP 15 / 1500
UP 20 / 2000
UP 25 / 2500

GENERAL

Model:

UP3UP6 UP10 UP15 UP20 UP25

Serial number:

Year of installation:

2011 20122013 2014 2015

Carrying capacity [kg]:

300 600 1000 1500 2000 2500

Travel [mm]:

Speed [m/s]:

Levels served:

23 4

Accesses:

1 accesso 2 accessi3 accessi

Platform dimension [mm]:

Standard: Length. 900mm; Width. 1300mm

Customised: Length: ______Width: ______

EXTERNAL SAFETY DEVICES AND COMPONENTS

Safety devices on ground level:

Gate or door with external electric lock

Door with integrated electric lock

Other______

Safety devices on other levela:

Gate or door with external electric lock

Door with integrated electric lock

Other ______

Control:

No. of pushbutton panels: ______

Deadman pushbutton panel

Pulse-operated pushbutton panel

TECHNICAL CABINET

Position on ground level:

0 -1 ______

Maximum distance from the lift shaft: 6 m

Environment:

Closed Protected ______

Technical cabinet dimensions:

Width: ______Depth: ______Height: ______

Access:

DirectIndirect through common rooms/property

Lighting:

Lighting in proximity of the control unit: ______LUX [≥200LUX]

Lighting in proximity of the electric cabinet ______LUX [≥200LUX]

Type of ventilation openings:

Cabinet vents towards a ventilated room and connected to the outside

Vent in the cabinet and connection tube to the outside

System according to the fire-fighting requirements

MOTOR AND ELECTRIC CIRCUIT

Standard components (BASIC outfitting):

Onboard the good:

Good lift levelmechanical limit switch

Platform positioning Mechanical limit switch

n.2 Proximity Safety hook ceck

Circuit board

External components:

Call buttons

Emergency stop button

Led onbuttons

Technical cabinet:

Up solenoid valve

Down solenoid valve

Optional components:

External components:

Exsternal electric lock

Standard doors

Doors with Kronemberg integrated electric lock

Emergency descent components

Onboard the good lift:

Emergency descent solenoid valve

HYDRAULIC SYSTEM

Gear pump:

Flow rate ______cc/g

Hydraulic oil/fluid type W.Engine HySy 22/B:

Density at 15°: 0.858 kg/l

cSt viscosity at 40°C: 23.8

Englar viscosity at 50°C: 2.3

Viscosity index: 105

Pour point: -33°C

VA flammability: 192°C

Aniline point: 96

DIN 51 524 HLP classification: 22

Maximum pressure: 160 bar

Suspension devices:

UP3

1 hydraulic cylinder with rigid tubes to a safety check valve

Rexroth VEI-8A-2A-06-NC-S-M

1chain type Flayer AL644 19.05mm Sedis, traction breakage 80 kN

UP6

1 hydraulic cylinder with rigid tubes to a safety check valve

Rexroth VEI-8A-2A-06-NC-S-M

1 chain type Flayer AL644 19.05mm Sedis, traction breakage 80 kN

UP10

1 hydraulic cylinder with rigid tubes to a safety check valve

Rexroth VEI-8A-2A-06-NC-S-M

2 chains type FlayerAL644 19.05mm Sedistraction breakage 80 kN

UP15

1 hydraulic cylinder with rigid tubes to a safety check valve

Rexroth VEI-8A-2A-06-NC-S-M

2 chains type Flayer AL644 19.05mm Sedistraction breakage 80 kN

UP20

1 1 hydraulic cylinder with rigid tubes to a safety check valve

Rexroth VEI-8A-2A-06-NC-S-M

2 chains type FlayerAL666 19.05mm Sedistraction breakage 115.8 kN

UP25

1hydraulic cylinder with rigid tubes to a safety check valve

Rexroth VEI-8A-2A-06-NC-S-M

2 chains type Flayer AL666 19.05mm Sedistraction breakage 115.8 kN

LIFT SHAFT

Reinforced concrete construction

Lift shaft dimensions [mm]:

Standard: Length. 1060mm; Width. 1360mm

Customised: Length: ______Width: ______

Maximum difference in height between levels [mm]:

Standard: 3000

Customised: ______

SAFETY DEVICES INSTALLED

UP3 e UP6 MODELS

Check valves

Rexroth VEI-8A-2A-06-NC-S-M

Maximum press: 350 bar

Maximum flow rate: 40 l/min

Electric drive: elettrico 24V DC

Ceck: proximity

Parachute valve

Rexroth VPN-OT.F4.01-03-02– valve against tube breakage

Mechanical safety hooks

Hydraulic device integrated in the goods lift system and controlled by proximity.

UP10 UP15 UP20 UP25 MODELS

Doble lift chain

Valvole di blocco

Rexroth VEI-8A-2A-06-NC-S-M

Maximum press: 350 bar

Maximum flow rate: 40 l/min

Electric drive: elettrico 24V DC

Ceck: proximity

Parachute valve

Rexroth VPN-OT.F4.01-03-02– valve against tube breakage

Mechanical safety hooks

Hydraulic device integrated in the goods lift system and controlled by 2 proximity.

GENERIC SAFETY DEVICES FOR ALL MODELS

Electric locks:

Pizzato FS2896D024-F

Degree of protection: IP66

Operating temperature: -25°C to 60°C

Voltage: 24VDC

Absorption: 1A

Mechanical life: 800,000 cycles

Retention force: 1100 N

Extraction force: 30 N

Pagina 1 di 14