LAOF Request Form – S-band Dual Polarization Doppler Radar (SPol)
NCAR S-Band Dual Polarization Doppler Radar (SPol)
Contact:
Dr. Tammy Weckwerth / / (303) 497-8790
https:
SPOL OPERATIONS
- Deployment location
- Deployment period
- Weather events during which collection is desired
- Typical attended radar operation schedule
- Estimated number of radar observation hours
- Please specify the desired mode of operation
- In addition to the standard attended operation mode, will you request “unattended remote off-site operations during which the radar can be scanned in a pre-specified scanning sequence or remotely controlled by a PI via internet? YES/NO
- Will you conduct Intensive Observing Periods (IOPs)? YES/NO
- If yes, under which circumstances?
- How long does each IOP last?
- Do you require the Ka-band wavelength radar?
- Please specify your communication needs (e.g., chat; internet bandwidth)
- How many of your staff will be available to help with S-Pol operations?
- What auxiliary equipment will be located at the radar site?
- If any, what are the size dimensions?
- Will equipment need to use S-Pol power exceeding 25 Amps?
- If so, will it require single or 3-phase power?
- 120 or 220 Volts?
- The standard S-Pol configuration has 3 scientific display stations and 3 additional seats with desk space. Is this sufficient to accommodate the maximum number of scientists and staff expected at S-Pol at any one time? YES/NO
- If no what additional space needs do you have?
- What office equipment (e.g., computers, printers, monitors) are you planning to bring to S-Pol?
TYPICAL RADAR PARAMETERS
- Please indicate if the following standard operating parameters are acceptable? If not please specify the requirement:
PRF = 1000 Hz (range = 500 to 1300Hz)
Max Range = 150 km
Unambiguous Velocity = 25 m s-1
Range Resolution = 150 m (150 to 675 m)
Type of Scans: Range Height Indicator (RHI), Plan Position Indicator (PPI), Vertically pointing, Staring
Scan Rate: RHI = 6 deg s-1 (1 to 6 deg s-1)
PPI = 10 deg s-1 (1 to 12 deg s-1)
Polarization transmitting mode:
Alternating Transmit (standard)
Simultaneous Transmit (available)
Standard S-band minimum sensitivity at various ranges:
-45 dBZ at 1 km
-25 dBZ at 10 km
-5 dBZ at 100 km
Standard Ka-band minimum sensitivity at various ranges:
-37 dBZ at 1 km
-17 dBZ at 10 km
Will the following list of standard real-time products be sufficient? Rain rate, (R-Z, R-Z/ZDR, R-KDP, R-KDP/ZDR, and a hybrid), Particle ID, Refractivity
If not please specify what else is desired.
- Scientific rationale for the non-standard but desired radar parameters
- Please specify your radar control needs
- Please specify your radar display needs
DATA ACCESS AND DISTRIBUTION
- Please specify your in-field real time data access needs for both S-Pol and auxiliary data.
- Will S-Pol data need to be distributed offsite in near real-time?
- Will you require recording of I and Q time series data? YES/NO
- If yes, approximately how many hours of recording are expected?
- Will post-project data distribution via ftp be sufficient? YES/NO
OTHER
- Do you have any special radar operating requirements that may require EOL development including but not limited to:
- COPLANE scanning
- SZ phase coding
- dual-wavelength LWC retrievals
- dual-wavelength humidity retrievals
- Fast switching between alternating and simultaneous transmit modes
- Do you have any special requirements that pertain to EOL support?