EntraPass Corporate Edition configuration for Integration with Victor

Requirements

  • Victor:
  • Unified Client and Site Manager v4.4 or higher
  • EntraPass Integration (ADVC-ENTRAPASS) V4.4 or higher
  • EntraPass:
  • EntraPass Corporate Edition v6.01.51 or higher
  • SmartLink installed
  • Webstation license activated(See Note 1)
  • Web Service configured
  • EntraPass operator dedicated for EntraPass integration
  • Windows Firewall Exception for Inbound Traffic on TCP 8801

Note 1: ONLY one Webstation license is included by default with EntraPass CE. If Victor EntraPass Integration is used, EntraPass Web & GO cannot be used unless additional licenses are purchased.

IMPORTANT:To ensure a successful integration, all EntraPass Components should be installed, configured and operational prior to Victor configuration.

Configuration

  • EntraPass:
  • Webstation license activation:
    From CE Server: General Tab/Registration, On the Left pane, select Webstation and click the “Click here to install component” button (See screenshot below)
    From a CE workstation: Options Tab/Registration, activate Webstation (as indicated above)

Note: Once the Webstation license is activated, a Data backup will be performed automatically.


  • Web Service Configuration:
    From a Workstation: Devices Tab/Applications/SmartLink/SmartLink Web and API Tab
  • Check Use Web Service
  • Set Web Service Protocol to http

  • Victor EntraPass Integration Operator:
    From a Workstation: System/Operator/New Operator
  • Login Tab
  • Name: Victor Access
  • Login name: VictorCE (Must be at least 8 characters)
  • Password: victor1 (Case-sensitive, must be at least 7-digit)
  • Enable Concurrent logins
  • Security Tab
  • Login Schedule: Always Valid
  • Security Level: Installer
  • Workspace: All
  • Web parameters
  • Enable Allow login
  • Enable Concurrent logins
  • Default message filter: All Events

See screenshots below:

1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450) 444-2029 •

Copyright © 2012 Tyco International Ltd. and its Respective Companies. • All rights reserved.

Specifications are subject to change without prior notice.

1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450) 444-2029 •

Copyright © 2012 Tyco International Ltd. and its Respective Companies. • All rights reserved.

Specifications are subject to change without prior notice.

1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450) 444-2029 •

Copyright © 2012 Tyco International Ltd. and its Respective Companies. • All rights reserved.

Specifications are subject to change without prior notice.

  • Windows Firewall Exception:
    If the Windows Firewall is enabled, a rule must be created to allow port TCP 8801 inbound traffic on all 3 profiles (Domain, Private and Public).
    Please refer to Windows documentation for instructions.

Once EntraPass configuration is complete, the SmartLink window should look like this:

1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450) 444-2029 •

Copyright © 2012 Tyco International Ltd. and its Respective Companies. • All rights reserved.

Specifications are subject to change without prior notice.