Food Service equipment Contractor to move four (4) existing
appliances to the left 10” on the existing a la carte cooking line (in plan view) and provide new 48” Dormont double swivel quick disconnects for these items.
ITEM NO 3 PLATFORM SCALE
Quantity Req'd.: 1
Status: Existing/Relocate
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by Product Supplier/ Vendor. Any utility connections indicated on drawings are representative and intended to assist the Engineer in planning base building utility systems. Utility requirements for existing equipment or equipment provided by a product supplier will be confirmed by the FSE Contractor and represented on the dimensioned rough-in plans for use by the construction trades.
ITEM NO 4 - SPARE NUMBER -
ITEM NO 5 - SPARE NUMBER -
ITEM NO 6 - SPARE NUMBER -
ITEM NO 7 ICE MAKER W/ BIN
Quantity Req'd.: 1
Manufacturer: Hoshizaki
Model No.: 1300
Status: Existing/Relocate
Connect to item 9, water filter.
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner. Any utility connections indicated on drawings are representative and intended to assist the Engineer in planning base building utility systems. Utility requirements for existing equipment or equipment provided by a product supplier will be confirmed by the FSE Contractor and represented on the dimensioned rough-in plans for use by the construction trades.
ITEM NO 8 ICE MAKER WITH BIN
Quantity Req'd.: 1
Manufacturer: Hoshizaki
Model No.: HOSHI
Status: Existing/Relocate
Connect to item 9, water filter.
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner. Any utility connections indicated on drawings are representative and intended to assist the Engineer in planning base building utility systems. Utility requirements for existing equipment or equipment provided by a product supplier will be confirmed by the FSE Contractor and represented on the dimensioned rough-in plans for use by the construction trades.
ITEM NO 9 WATER FILTER
Quantity Req'd.: 1
Manufacturer: Everpure, Inc
Model No.: EV9347-20
Status: In Contract
Provide with:
Replacement cartridge EV9613-10
EC210 prefilter cartridge.
SS-IMF Cartridge EV9799-32
Connect to items 7 and 8.
ITEM NO 10 FLOOR TROUGH
Quantity Req'd.: 1
Manufacturer: IMC/Teddy
Model No.: SFT
Status: In Contract
Unit of size and shape as shown on plan. This item to be set and installed by General Contractor. Quarry tile floor finish to be etched, if required, prior to setting food service equipment in place. Provide grating sections of equal size not to exceed 20" long. Provide shop drawings of size and scale outlined in specific conditions.
- Grating to be anti-slip, stainless steel.
- Shallow floor trough, 2" deep
- Standard troughs up to 96" long have one waste at center. Over 96", troughs have two wastes equidistant.
- Seepage flange and "weep" holes (for above grade application only).
ITEM NO 11 - SPARE NUMBER -
ITEM NO 12 - SPARE NUMBER -
ITEM NO 13 - SPARE NUMBER -
ITEM NO 14 HAND SINK
Quantity Req'd.: 4
Manufacturer: IMC/Teddy
Model No.: CSW
Status: In Contract
IMC/Teddy Model No. CSW, Hand Sink.
- Heavy duty gooseneck faucet w/wrist handles.
- Provide hose bibs under 2 units.
ITEM NO 15 SHELVING
Quantity Req'd.: LOT
Manufacturer: Metro Equip
Model No.: Super Erecta
Status: In Contract
Metro Equip Model No. SUPER ERECTA, Of size and shape as shown on plan x 4 tiers high. 74" high posts to match shelf type.
ITEM NO 16 - SPARE NUMBER -
ITEM NO 17 DUNNAGE RACK
Quantity Req'd.: 1
Manufacturer: Metro Equip
Model No.: MHP55K3
Status: In Contract
Dunnage Rack.
- Furnish per manufacturer's standard specifications.
ITEM NO 18 RACK, UTILITY - UNIVERSAL ANGLE
Quantity Req'd.: 2
Status: Existing/Relocate
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner.
ITEM NO 19 - SPARE NUMBER -
ITEM NO 20 - SPARE NUMBER -
ITEM NO 21 FISH AND POULTRY STORAGE RACK
Quantity Req'd.: 1
Manufacturer: Refrigerator Manufacturers Inc.
Model No.: CXA-619
Status: In Contract
Provide with 3 McClintock lugs 11” H x 19” W X 25” D
ITEM NO 22 SHELVING
Quantity Req'd.: LOT
Manufacturer: Metro Equip
Model No.: METROSEAL 3
Status: In Contract
Of size and shape as shown on plan x 4. 74" high posts to match shelf type. 5" diameter polyurethane swivel casters, two (2) with brakes.
ITEM NO 23 CABINET, UTILITY
Quantity Req'd.: 3
Status: Existing/Relocate
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner.
ITEM NO 24 WALK-IN COOLER
Quantity Req'd.: 1
Manufacturer: Kolpak Ind Inc
Model No.: Custom
Status: In Contract
Kolpak Ind Inc COOLER/ FREEZER Unit to be a Refrigerator +35° F. and Freezer -10° F. of size and shape as shown on plan 8'-6" high. Wall and ceiling panels shall be 4" urethane, U.L.Flame Spread 25 insulation. Panels are without wooden structural members. Hinged entrance door(s) to be flush type, hinged as shown on plan. Thru ceiling door electrical assembly as shown on detail E-1-4. Provide one (1) lot removable closure panels with channels, the same finish as exterior panels to ceiling. (F.S.E. Contractor to verify ceiling height). One (1) lot of trim strip, where required to close in wall gaps, of same finish as exterior panels to finished ceiling. (F.S.E. Contractor to verify height).
Combination cooler/ freezer. Cooler with 2” factory floor in cooler and 4” factory floor in freezer with internal ramp.
- Protect-all vinyl finish flooring coved 6” to all interior walls to be provided and installed by FSEC.
- Embossed aluminum white interior and exposed exterior. Unexposed exterior finish to be galvalume.
- Hinged doors to be 36" wide x 78" high with third hinge.
- Dead bolt lock per Specific Conditions (on exterior doors only)
- Anti-condensate heaters in full perimeter of door and frame (freezer only)
- Aluminum diamond tread kick plate, 3'-0" high on exterior and interior of door and jamb
- 14" x 14" vision panel and automatic door closer, Kason K-1094.
- Factory cut door for tile floor conditions.
- Lithonia florescent light fixtures and switches, installed and wired by the Electrical Division per detail E-1-4. (See electrical plan for quantity and location of lights and switches).]
- Modularm 75B, recessed with thru ceiling door electrical as shown on detail E-1-4.
- FSE Contractor to provide complete and operable refrigeration system.
ITEM NO 25 TABLE, ISLAND TYPE
Quantity Req'd.: 1
Manufacturer: Custom Fabricated Assembly,
Status: In Contract
Unit to be of size and shape as shown on plan x 36” high per detail C-7-1C. Type “A” edge per detail C-1-1A. Provide with the following:
- One -20" x 20" x 5" deep utility drawer per detail C-1-3A,C-1-3B, C-1-3C and C-1-3D. Lock hasp.
- Mount on set of 5" diameter polyurethane swivel casters, two (2) diagonal with brakes.
ITEM NO 26 COUNTERW/2-SINKS
Quantity Req'd.: 1
Status: Existing/Relocate
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner. Any utility connections indicated on drawings are representative and intended to assist the Engineer in planning base building utility systems. Utility requirements for existing equipment or equipment provided by a product supplier will be confirmed by the FSE Contractor and represented on the dimensioned rough-in plans for use by the construction trades.
ITEM NO 27 RACK, WORKING HEIGHT
Quantity Req'd.: 2
Manufacturer: Eagle
Model No.: OUR-1807-3-SR
Status: In Contract
Panco aluminum pan stop
Casters with locking brakes, set of 2
ITEM NO 28 BUTCHER BLOCK
Quantity Req'd.: 1
Status: Existing/Relocate
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner.
ITEM NO 29 SAW, MEAT 16" CUT CLEARANCE
Quantity Req'd.: 1
Status: Existing/Relocate
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner. Any utility connections indicated on drawings are representative and intended to assist the Engineer in planning base building utility systems. Utility requirements for existing equipment or equipment provided by a product supplier will be confirmed by the FSE Contractor and represented on the dimensioned rough-in plans for use by the construction trades.
ITEM NO 30 - SPARE NUMBER -
ITEM NO 31 - SPARE NUMBER -
ITEM NO 32 SPREADER CABINET
Quantity Req'd.: 1
Manufacturer: Garland Ind
Model No.: M12ES
Status: In Contract
Spreader Plate, approximately 12" wide top, cabinet base with one door, stainless steel top, left side and front, for 38" deep range units.
ITEM NO 33 EXHAUST HOOD, WALL MOUNTED
Quantity Req'd.: 1
Manufacturer: Gaylord, Inc.
Model No.: Island GX2-BDL
Status: In Contract
Unit to be U.L. listed grease extractor, high velocity wall mounted canopy of size and shape as shown on plan 9’-6"x 68” deep x 30" high, built in 1 section(s) and mounted 6'-8" AFF. One (1) lot stainless steel enclosure paneling, at all open sides, to finished ceiling (F.S.E. Contractor to verify height). Paneling must be supplied by Exhaust Hood Manufacturer and installed by F.S.E. Contractor. Adhere to Specific Conditions for installation of fabricated equipment." Ventilator to be U.L. and NSF listed and be in full accordance with NFPA 96 and all state/local codes/ordinances applicable. F.S.E. Contractor to supply the necessary mounting rods for hanging ventilator. Supply and/ or exhaust air requirements as shown on plans.
Options:
- Recessed incandescent light fixtures as indicated on electrical plan.
- Exhaust collar(s) with thermostatically activated fire damper,
- Pre-piping of the Item No 165, Fire protection system is to be provided by the Exhaust Hood manufacturer at the time of hood fabrication.
- Pre-piping to include fusible-link detector bracket assemblies and cable runs, and wet-chemical manifold piping, duct collar and plenum protection piping with termination nozzles, and cooking appliance nozzle drops with termination nozzles.
- Location of cooking appliance nozzle drops are to be fully dimensioned on hood submission drawings.
- Fusible link detector and wet chemical piping terminations to be coordinated with the FSE Contractor and clearly indicated on hood submission drawings.
- Access to the fusible links for inspection and change-outs to be provided. The hood manufacturer and FSE Contractor to coordinate their efforts to assure the necessary access.
FSE Contractor is responsible for fit of equipment. Prior to releasing hoods for fabrication, FSE Contractor needs to verify field conditions (existing &/or proposed) and to determine clearances to all structural items, obstructions, etc. The FSE Contractor will coordinate with other trades to confirm that the hood can be mounted as proposed and that the ductwork and final connection can be accommodated without conflict. Failure to perform this step may result in modifications to the exhaust hood at the FSE Contractor's expense.
ITEM NO 34 WALL FLASHING, STAINLESS STEEL
Quantity Req'd.: 1
Manufacturer: Custom Fabricated Assembly,
Status: In Contract
Provide 22 ga. stainless steel wall flashing, approximately ' per detail C-2-11. Stainless steel flashing to extend from floor or top of wall tile base to top of 48” high wall with s.s. wall cap per detail ED-106
ITEM NO 35 OVEN, CONVECTION, GAS
Quantity Req'd.: 1
Manufacturer: Blodgett Co.
Model No.: DFG100 DOUBLE X-CEL
Status: In Contract
Oven, Convection, Natural gas
- Solid State digital control with LED display, cook & hold, and Pulse Plus and humidaire control.
- 4.25" low profile casters (double only)
- Flexible gas hose w/quick disconnect & restraining device.
- Interior liner stainless steel.
- Solid back and right side panel stainless steel
- Gas manifold (double section).
ITEM NO 36 RANGE, HEAVY DUTY GAS
Quantity Req'd.: 1
Manufacturer: Garland
Model No.: M43R
Status: In Contract
Range, Heavy-Duty, Gas-Fired
Provide with the following:
- ¾” rear gas connection.
- Right and left end caps.
- Provide with flexible gas disconnects.
- 10” flue riser.
- 4 swivel casters, two locking.
- Provide with shield 12” tall on right side
ITEM NO 37 KETTLE & POT FILLER
Quantity Req'd.: 1
Manufacturer: T & S, Inc.
Model No.: B-0610
Status: In Contract
Faucet, Service Sink. Mount on wall behind item 32, spreader.
ITEM NO 38 FRYER, DEEP FAT, GAS-FIRED
Quantity Req'd.: 1
Manufacturer: Vulcan-Hart
Status: Existing/Relocate from main cooking line.
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner. Any utility connections indicated on drawings are representative and intended to assist the Engineer in planning base building utility systems. Utility requirements for existing equipment or equipment provided by a product supplier will be confirmed by the FSE Contractor and represented on the dimensioned rough-in plans for use by the construction trades.
ITEM NO 39 UTILITY CHASE
Quantity Req'd.: 1
Manufacturer: Custom Fabricated Assembly,
Status: In Contract
Unit to be a divided chase of size and shape as shown on plan per detail C-2-12. F.S.E. Contractor to verify ceiling height. Unit to be built as a part of item 42, table with sink.
- Extend chase to finished ceiling.
ITEM NO 40 CABINET, WALL-MOUNTED
Quantity Req'd.: 1
Status: Specified By Architect/Interior Designer
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner.
ITEM NO 41 OFFICE CHAIR
Quantity Req'd.: 1
Status: Specified By Architect/Interior Designer
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner.
ITEM NO 42 TABLE W/SINK, TABLE MOUNTED OVERSHELF
Quantity Req'd.: 1
Manufacturer: Custom Fabricated Assembly,
Status: In Contract
CUSTOM FABRICATE, Unit to be of size and shape as shown on plan x 36” high per detail C-7-1B and C-8-5 with Type “V” edge per detail C-1-1A, one 20” x 20” x14” deep drawn sink, closed backsplash per detail C-1-1B.
- Flanged feet.
- Provide with type 3 faucet w/ 12” swing spout.
- One -20" x 20" x 5" deep utility drawer per detail C-1-3A,C-1-3B, C-1-3C and C-1-3D. Lock hasp.
- Provide with table mounted overshelf and utensil rack per details C-1-6 and C-7-5
ITEM NO 43 FREEZER, 1-SECTION
Quantity Req'd.: 1
Manufacturer: HOSHIZAKI
Status: Existing/Relocate
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner. Any utility connections indicated on drawings are representative and intended to assist the Engineer in planning base building utility systems. Utility requirements for existing equipment or equipment provided by a product supplier will be confirmed by the FSE Contractor and represented on the dimensioned rough-in plans for use by the construction trades.
ITEM NO 44 TABLE W/ TABLE MOUNTED SHELF
Quantity Req'd.: 1
Manufacturer: Custom Fabricated Assembly,
Status: In Contract
CUSTOM FABRICATE, Unit to be of size and shape as shown on plan x 36” high per detail C-7-1C and C-8-5 with continuous seamless flush front Type “V” edge per detail C-1-1A, closed backsplash per detail C-1-1B.
- Provide with table mounted overshelf per details C-1-6.
- Mount on set of 5" diameter polyurethane swivel casters, two (2) diagonal
with brakes.
ITEM NO 45 VACUUM PACKAGING UNIT
Quantity Req'd.: 1
Manufacturer: Vacmaster
Model No.: SVP-20
Status: Existing/Relocate
This item is not in contract. The specification is for reference only. The item is shown on the drawing for informational purposes and generally represents the size/ capacity of unit to be provided by the owner. Any utility connections indicated on drawings are representative and intended to assist the Engineer in planning base building utility systems. Utility requirements for existing equipment or equipment provided by a product supplier will be confirmed by the FSE Contractor and represented on the dimensioned rough-in plans for use by the construction trades.
ITEM NO 46 FISH PREP STATION
Quantity Req'd.: 1
Manufacturer: Custom fabricated
Status: In Contract
Custom fabricated, Sink Work Table, One Compartment, stainless steel top, w/raised-inverted “V” non-spill edges, 10" w/rear, left & right-hand splash, stainless steel open frame base, with stainless steel tubular undershelves per detail C-8-5-C and C-7-1. Size and shape as shown on plan. Sink to be 5” deep. Provide with:
- Fisher 2210-WB pre-rinse with 2901 Add on faucet
- 48" x 14" x 3/4" thick richlite cutting board inset in top.
- Removable s.s. perforated false bottom w/1" finger hole.
- Tool drawer w/padlock hasp per details C-1-3-A,B,C,D.
- Integral hand sink below top per detailC-2-1-D
ITEM NO 47 - SPARE NUMBER -
ITEM NO 48 - SPARE NUMBER -
ITEM NO 49 - SPARE NUMBER -
ITEM NO 50 - SPARE NUMBER -
ITEM NO 51 REFRIGERATOR, 1-SECTION
Quantity Req'd.: 1
Manufacturer: Beverage Air
Model No.: MT 12 Marketeer
Status: In Contract
Refrigerator, 1-Section
- Provide with glass door hinged per plan drawing.
- Furnish w/ cord & plug
- Unit to be on swivel casters, 2 locking.
- Door w/ cylinder lock.
- Provide five (5) year compressor warranty and one (1) year refrigeration service contract.
- Provide condensate evaporator.
ITEM NO 52 FIRE SUPPRESSION SYSTEM
Quantity Req'd.: 1
Manufacturer: Kidde
Model No.: WHDR
Status: Existing/Relocate/Modify or replace
The cooking line has been expanded by 69” to provide items 117, 118, 119, and 120. As this now becomes all in the same hazard zone, the existing system must be moved to a new location and modified or replaced with a new system. FSEC to confirm with fire suppression sub-contractor what will be required prior to bid submission. No allowance will be made later for additional cost not anticipated at the time of bid.