SPECIFICATION FOR
KERBS/EDGINGS/CHANNELS/PAVING ACCESSORIES
SECTION Q10
Revision / Date / Issue Authorised ByApproved for Issue
Date
To be read with Preliminaries/ General conditions.
TYPES OF KERBS, EDGINGS AND CHANNELS
112PRECAST CONCRETE KERBS
Standard: To BS EN 1340.
Designations: HB2
Size (width x height x length): 125mm x 255mm x 914mm
Special shapes: n/a
Finish: as cast
Colour: grey
Bending strength: 4.0
Weathering resistance: Class 3
Abrasion resistance: Class 1
Slip / skid resistance: n/a
Bedding: concrete grade ST4
Joints generally: open, 2-3 mm gap
Sealant movement joints: n/a
113 PRECAST CONCRETE KERBS
Standard: To BS EN 1340
Designations: BN
Size (width x height x length): 150mm x 125mm x 914mm
Finish: as cast
Colour: grey
Bending strength: 4.0
Weathering resistance: Class 3
Abrasion resistance: Class 1
Slip / skid resistance: n/a
Bedding: concrete grade ST4
Joints generally: open, 2-3 mm gap
Sealant movement joints: n/a
114PRECAST CONCRETE KERBS
Standard: To BS EN 1340
Designations: EF
Size (width x height x length) 50mm x 150mm x 914mm
Finish: as cast
Colour: grey
Bending strength: 4.0
Weathering resistance: Class 3
Abrasion resistance: Class 1
Slip / skid resistance: n/a
Bedding: concrete grade ST4
Joints generally: open, 2-3 mm gap
Sealant movement joints: n/a
180DRAINAGE CHANNEL SYSTEMS WITH GRATINGS TO PAVED AREAS
Manufacturer: ACO or similar approved
-Product reference: N100K
Size: 130 mm
Type of fall: laid to falls
Finish: as cast
Colour: grey
Accessories: sump units
Bedding: concrete grade ST4
Joints generally: manufacturer’s specification
Cover gratings: galvanised steel
-Fixings: mechanical
-Loading grade to BS EN 124: pedestrian
-Finish/ Colour: galvanised
ROADS/ PAVING ACCESSORIES/ MARKING
395ROAD MARKING (THERMOPLASTIC)
Standard: Road Safety Markings Association standard specification document for road marking and road studs (StanSpec).
Manufacturer: Contractor’s choice
- Product reference: n/a
Colour: white
Retroreflectivity to BS EN 1436: Class R2
396 ROAD MARKINGS (THERMOPLASTIC)
Standard: Road Safety Association standard specification document for road markings and
road studs (StanSpec)
Manufacturer: Contractor’s choice
- Product reference: n/a
Colour: yellow
Retroreflectivity to BS EN 1436: n/a
LAYING
510 ALAYING KERBS, EDGINGS AND CHANNELS
Cutting: Neat, accurate and without spalling using a masonry saw where necessary. Form neat junctions.
-Length of cut kerb, channel or edging: Not less than 450mm.
-Length of cut bricks and blocks: Not less than one third of their original length.
Bedding of units: Positioned true to line and levelled along top and front faces, in a mortar bed on accurately cast foundations or on a race of fresh concrete.
Securing of units: After bedding has set, secured with a continuous haunching of concrete or on a race of fresh concrete with backing concrete cast monolithically.
Exposed faces of units: Keep clean and free from concrete and mortar droppings.
520ADVERSE WEATHER
Conditions: Do not construct if the temperature is below 3°C on a falling thermometer or 1°C on a rising thermometer. Adequately protect foundations, bedding and haunching against frost and rapid drying by sun and wind.
530 ACONCRETE FOR FOUNDATIONS, RACES AND HAUNCHING
Standards: To BS 8500-2.
Standard Mix: ST4 or better.
Workability: Very low
540CEMENT MORTAR BEDDING
General: To section Z21.
Mix (Portland cement:sand): 1:3.
-Portland cement: Class CEM l 42.5 to BS EN 197-1.
-Sand: To BS EN 12620, grade 0/4 or 0/2 (MP).
Bed thickness: 12–40mm
547BEDDING/ BACKING OF UNITS ON FRESH CONCRETE RACES
Standard: To BS 7533-6.
570CHANNELS
Installation: To an even gradient, without ponding or backfall.
Lowest points of channels: 6mm above drainage outlets.
580DRAINAGE CHANNEL SYSTEMS
Installation: To an even gradient, without ponding or backfall. Commence laying from outlets.
Silt and debris: Removed from entire system immediately before handover.
Washings and detritus: Safely disposed without discharging into sewers or watercourses.
590DRAINAGE CHANNEL SYSTEMS WITH BUILT IN FALL
Installation: Top of channels level, installed in correct sequence to form an even gradient without ponding or backfall. Commence laying from outlets.
Silt and debris: Removed from entire system immediately before handover.
Washings and detritus: Safely disposed without discharging into sewers or watercourses.
600RADIUS KERBS/ CHANNELS
Usage: Radii of 15m or less.
610ANGLE KERBS
Usage: Internal and external 90° changes of direction.
Cutting of mitres: Not permitted.
615 BTAPER KERBS
Usage: Where kerb face reduces to dropped kerbs.
620ACCURACY
Deviations (maximum):
-Level: 6mm.
-Horizontal and vertical alignment: 3mm in 3m.
630NARROW MORTAR JOINTS
Jointing: Ends of units buttered with bedding mortar as laying proceeds. Joints completely filled, tightly butted and surplus mortar removed immediately.
-Joint width: 3mm.
631 BDRY BUTT JOINTS
Tightly butt kerbs together.
-Joint width: 2mm.
640TOOLED MORTAR JOINTS
Jointing: Ends of units buttered with bedding mortar as laying proceeds. Joints completely filled and tooled to a neat flush profile.
-Joint width: 6mm.
Author HE / BETTWS SCHOOL, NEWPORT / SC0094009/07 / Rev
clarkebond / Page 1 of 4