SECTION 08420
FIRE RATED STEEL FRAMED ENTRANCES AND STOREFRONT
Display hidden notes to specifier. (Don't know how? Click Here)
Copyright 2010 - 2013 ARCAT, Inc. - All rights reserved
** NOTE TO SPECIFIER ** Vetrotech - Fire-Rated Glass & Systems; Fire-Rated Steel Framed Entrances and Storefront.
This section is based on the products of Vetrotech - Fire-Rated Glass & Systems, which is located at:
2108 B St. N. W. Suite 110
Auburn, WA 98001
Toll Free Tel: 888-803-9533
Tel: 253-333-0660
Fax: 253-333-5166
Email: request info ()
Web: www.vetrotechusa.com
[ Click Here ] for additional information.
Specialists in fire rated glass products, Vetrotech - Fire-Rated Glass and Systems is recognized worldwide as an industry leader. For over 300 years companies have trusted the Saint-Gobain companies for high quality building products. Working with Vetrotech - Fire-Rated Glass and Systems you'll benefit from Saint-Gobain's global network of research and development facilities, producing the industry's broadest range of clear fire rated glass, fire rated ceramic and heat absorbing laminates.
Fire rated glass safety testing specialists in fire rated glass products, Vetrotech - Fire-Rated Glass and Systems is recognized worldwide as an industry leader. We perform over 500 fire tests per year. Vetrotech - Fire-Rated Glass and Systems products are tested and listed in accordance with all United States and Canadian national standards by Underwriters Laboratory and Warnock Hersey/Intertek Testing Services. All Vetrotech - Fire-Rated Glass and Systems products meet or exceed all building code requirements.
PART 1 GENERAL
1.1 SECTION INCLUDES
** NOTE TO SPECIFIER ** Delete items below not required for project.
A. Fire rated glazing, framing systems and hardware for the following applications:
1. Interior vision lights and frames.
2. Interior doors and frames.
3. Exterior insulated vision lights and frames.
4. Exterior insulated doors and frames.
1.2 RELATED SECTIONS
** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
A. Section 05500 - Metal Fabrications; steel attachment members inserts and anchors for concrete or masonry.
B. Section 07250 - Weather Barriers; perimeter air, water and vapor seal between the work of this section and adjacent construction.
C. Section 07620 - Sheet Metal Flashing and Trim; flashing between this work and other work, concealed flashing.
D. Section 07840 - Firestopping; firestops between work of this section and other fire resistive assemblies.
E. Section 08113 - Hollow Metal Doors and Frames; hollow metal doors prepped for the work of this section.
F. Section 08710 - Door Hardware; door hardware other than that provided by the work of this section.
G. Section 08735 - Automatic Door Operators; opener for door to comply with ADA and Local Authority opening force requirements.
1.3 REFERENCES
** NOTE TO SPECIFIER ** Delete standards AAMA 2603 through 2605 according to type of finish specified in Part 2. For most applications, if the system is used for an interior application then all air and water infiltration testing and standards may be deleted. Delete references from the list below that are not actually required by the text of the edited section.
A. ASTM International (ASTM):
1. ASTM A 1008/A 1008M - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength, Low Alloy, and High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable.
2. ASTM A 1011/A 1011M - Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength.
3. ASTM E 283 - Test Method for Determining the Rate of Airflow through Exterior Windows, Curtain Walls, and Doors under Specified Pressure Differences across the Specimen.
4. ASTM E 90 - Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements.
5. ASTM E 119 - Methods for Fire Tests of Building Construction and Materials.
6. ASTM E 330 - Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference.
7. ASTM E 331 - Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference.
8. ASTM E 413 - Standard Classification for Rating Sound Insulation.
9. ASTM E 547 - Test Method for Water Penetration of Exterior Windows, Curtain Walls and Doors by Cyclic Static Air Pressure Difference.
10. ASTM E 783 - Test Method for Field Measurement of Air Leakage through Installed Exterior Windows and Doors.
11. ASTM E 1105 - Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform or Cyclic Static Air Pressure Difference.
12. ASTM F1915 - Standard Test Methods for Glazing for Detention Facilities
B. American Architectural Manufacturers Association (AAMA):
1. AAMA 501.1 - Standard Test Method for Water Penetration of Windows, Curtain Walls, and Doors Using Dynamic Pressure.
2. AAMA 501.2 - Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems.
3. AAMA 501.4 - Recommended Static Test Method for Evaluating Curtain Wall and Storefront Systems Subjected to Seismic and Wind Induced Interstory Drifts.
4. AAMA 501.5 - Test Method for Thermal Cycling of Exterior Walls.
5. AAMA 2603 - Voluntary Specification, Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum Extrusions and Panels.
6. AAMA 2604 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels.
7. AAMA 2605 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels.
C. American Welding Society (AWS):
1. AWS D1.3 - Structural Welding Code - Sheet Steel.
D. Builders Hardware Manufacturers Association, Inc.:
1. BHMA A156 - American National Standards for door hardware; (ANSI/BHMA A156).
E. Canadian Standards:
1. CAN4-S104-M, "Fire Tests of Door Assemblies
2. CAN4-S106-M, "Standard Method for Fire Tests of Window and Glass Block Assemblies"
F. National Fire Protection Association (NFPA):
1. NFPA 80: Fire Doors and Windows.
2. NFPA 251: Fire Tests of Building Construction and Materials.
3. NFPA 252: Fire Tests of Door Assemblies.
4. NFPA 257: Fire Test of Window Assemblies.
G. Underwriters Laboratories, Inc. (UL):
1. UL 9: Fire Tests of Door Assemblies.
2. UL 10 B: Fire Tests of Door Assemblies.
3. UL 10 C: Positive Pressure Fire Tests of Window and Door Assemblies.
4. UL 263: Fire tests of Building Construction and Materials.
5. UL 752: The Standard of Safety for Bullet-Resisting Equipment.
6. UL 972: Burglary Resisting Glazing Material.
H. Consumer Product Safety Commission (CPSC):
1. CPSC 16 CFR 120: Safety Standard for Architectural Glazing Materials.
1.4 SUBMITTALS
A. Submit under provisions of Section 01300.
B. Product Data: Submit manufacturer's descriptive literature, specifications, installation instructions, warranty, and laboratory test data.
C. Shop Drawings:
1. Include plans, elevations and details of product showing component dimensions; framed opening requirements, dimensions, tolerances, and attachment to structure.
2. Provide templates for the location of embeds and anchor locations required any adjoining work.
D. Calculations: For the performance requirements listed below requiring structural design provide data, calculations and Drawings signed and sealed by an engineer licensed in the state or province where the project is located.
E. Glazing Schedule: Use same designations indicated on Drawings for glazed openings in preparing a schedule listing glass types and thicknesses for each size opening and location.
** NOTE TO SPECIFIER ** Delete selection samples for glass type if glazing has already been selected.
F. Selection Samples for Glass Type and Color: For each glazing type specified, two samples representing manufacturer's full range of available styles and finishes.
G. Verification Samples for Glass Type and Color: For each product specified, two samples, two samples that are 6 inches by 6 inches (152 mm by 152 mm), representing actual product and finishes.
H. Test Reports: Certified test reports showing compliance with specified performance characteristics and physical properties.
I. Installer Qualification Data: For firms and persons specified in "Quality Assurance" Article to demonstrate their capabilities and experience. Include lists of completed projects with project names and addresses, names and addresses of architects and owners, and other information specified.
J. Field Quality-Control Reports.
K. Maintenance Data.
L. Warranties: Submit manufacturer's warranty and ensure that forms have been completed in the Owner's name and registered with the manufacturer.
1.5 PERFORMANCE REQUIREMENTS
A. Fire Rating Requirements: As specified in Part 2 of this section.
** NOTE TO SPECIFIER ** For exterior units fill in blanks below with wind load design pressure in psf and include applicable building code.
B. Structural Performance:
1. Wind loads: Provide system; include anchorage, capable of withstanding wind load design pressures of ____ lbs./sq. ft. inward and ____ lbs./sq. ft. outward. The design pressures are based on the (____) Building Code.
2. Air Infiltration: The test specimen shall be tested in accordance with ASTM E 283. Air infiltration rate shall not exceed 0.06 cfm/ft2 (0.3 l/(s x m2)) at a static air pressure differential of 6.27 psf.
3. Water Resistance, Static: The test specimen shall be tested in accordance with ASTM E 331. There shall be no leakage at a static air pressure differential of 15 psf as defined in AAMA 501.
4. Water Resistance, Dynamic: The test specimen shall be tested in accordance with AAMA 501.1. There shall be no leakage at an air pressure differential of 15 psf as defined in AAMA 501.
5. Uniform Load: A static air design load of 50 psf (2394 Pa) shall be applied in the positive and negative direction in accordance with ASTM E 330. There shall be no deflection in excess of L/175 of the span of any framing member at design load. At structural test load equal to 1.5 times the specified design load, no glass breakage or permanent set in the framing members in excess of 0.2 percent of their clear spans shall occur.
** NOTE TO SPECIFIER ** Coordinate the level of bullet resistance with the type of glazing selected in Part 2 of this specification. Delete bullet resistance rating not required.
6. Bullet Resistance: Provide systems that meet a bullet resistance level of 1 for glass when tested per UL 752.
7. Bullet Resistance: Provide systems that meet a bullet resistance level of 2 for glass when tested per UL 752.
8. Bullet Resistance: Provide systems that meet a bullet resistance level of 3 for glass when tested per UL 752.
9. Bullet Resistance: Provide systems that meet a bullet resistance level of 4for glass when tested per UL 752.
10. Bullet Resistance: Provide systems that meet a bullet resistance level of 5 for glass when tested per UL 752.
11. Bullet Resistance: Provide systems that meet a bullet resistance level of 6 for glass when tested per UL 752.
12. Bullet Resistance: Provide systems that meet a bullet resistance level of 7 for glass when tested per UL 752.
13. Bullet Resistance: Provide systems that meet a bullet resistance level of 8 for glass when tested per UL 752.
** NOTE TO SPECIFIER ** Delete detention rating not required.
14. Detention Rating: Provide systems that meet a security Grade 1 for glass when tested per ASTM F 1915.
15. Detention Rating: Provide systems that meet a security Grade 2 for glass when tested per ASTM F 1915.
16. Detention Rating: Provide systems that meet a security Grade 3 for glass when tested per ASTM F 1915.
17. Detention Rating: Provide systems that meet a security Grade 4 for glass when tested per ASTM F 1915.
** NOTE TO SPECIFIER ** Delete burglary rating not required.
18. Burglary Rating: Provide systems that meet a security level for glass, frames and doors when tested per UL 972.
1.6 QUALITY ASSURANCE
** NOTE TO SPECIFIER ** Delete if not required.
A. Manufacturer Qualifications: Manufacturer shall have five years experience manufacturing and fabricating products of similar type and scope as those specified in this section.
** NOTE TO SPECIFIER ** Fill in blank below or delete if not required.
B. Testing Agency Qualifications: ______.
C. Installer Qualifications: An experienced installer who has completed glazing similar in material, design, and extent to that indicated for this Project; whose work has resulted in glass installations with a record of successful in-service performance; and who employs glass installers for this Project who are certified under the National Glass Association Glazier Certification Program as Level 2 (Senior Glaziers) or Level 3 (Master Glaziers).
** NOTE TO SPECIFIER ** Delete paragraph above or below. If retaining above, verify with prospective installers that they can comply with glazier certification requirements.
D. Installer Qualifications: An experienced installer who has completed glazing similar in material, design, and extent to that indicated for Project and whose work has resulted in construction with a record of successful in-service performance.
E. Source Limitations for Glazing Accessories: Obtain glazing accessories from one source for each product and installation method indicated.
** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
F. Mock-Up: Provide a mock-up for evaluation of materials and workmanship.
1. Finish areas designated by Architect.