APPROVED BY
Order No. D1-476 of the Minister of Environment of the Republic of Lithuania of 9 June 2011
LIST OF CONTROLLED CONSTRUCTION PRODUCTS
NOTES AND EXPLANATIONS:
1) Requirements for construction products are specified in the List of Regulated Construction Products in accordance with requirements of Council Directive 89/106/EEC of 21 December 1988 “On the approximation of laws, regulations and administrative provisions of the Member States relating to construction products” whose provisions were transposed by the Law on Construction and technical construction regulations. Requirements of other EU directives, regulations and legal acts not listed here can be applicable to construction products.2) (D) - harmonised standard. The date next to the harmonised standards indicates from which only the harmonised standard is applied to a construction product.
3) ETL - European technical approval prepared according to recommendations approved by the European Organisation for Technical Approvals (EOTA) – ETAG.
4) Technical approval, company’s standard can also be technical specification of a construction product.
5) Systems of attestation of conformity are specified according to STR 1.01.04:2002, Annex 2 (Official Gazette, 2002, No. 54-2140).
6) The standard specifies special requirements applicable depending on a product area declared by the manufacturer.
7) NTL - national technical approval prepared according to STR 1.03.03:2008 (Official Gazette, 2008 No. 47-1762). / * - date from which only the indicated technical specification is applied to a construction product.
** - when provided for in the technical specification of a construction product.
*** - conformity of cement according to the content of alkali is evaluated according to “Matrix and silicate ware” methodology of 25th Technical Committee (LST TK 25) of the Lithuanian Standards Board.
**** - testing shall be necessary to determine the reaction-to-fire class when the declared reaction-to-fire class is other than FROOF(t1) FFL or when the reaction-to-fire class is not chosen from tables of technical construction regulations.
No. / Description of a construction product / Reference of technical specification of a construction product / Mandatory indicators / Reference of a standard regulating the test method or of other document / Conformity assessment scheme
1 / 2 / 3 / 4 / 5 / 6 /
1. / AGGREGATES
1.1 / Aggregates for concrete / LST EN 12620:2003+A1:2008(D) / indicators specified in the standard according to intended use of the product / LST EN 12620 / 2+
1.2 / Aggregates for mortar / LST EN 13139:2003(D) / indicators specified in the standard according to intended use of the product / LST EN 13139 / 2+
LST EN 13139+AC:2004 (D)
1.3 / Lightweight aggregates for concrete, mortar and grout / LST EN 13055-1:2004(D) / indicators specified in the standard according to intended use of the product / LST EN 13055-1 / 2+
LST EN 13055-1:2003/AC:2005
1.4 / Lightweight aggregates for bituminous mixtures and surface / LST EN 13055-2:2004(D) / indicators specified in the standard according to intended use of the product / LST EN 13055-2 / 2+, 4
treatments and for unbound and bound applications
1.5 / Aggregates of bituminous mixtures and surface treatment layer for / LST EN 13043:2003(D) / indicators specified in the standard according to intended use of the product / LST EN 13043+AC / 2+
roads, airfields, and other trafficked areas / LST EN 13043:2003/AC:2004(D)
LST EN 13043+AC:2004(D)
1.6 / Activated mineral powder for asphalt concrete mixtures / LST 1419:1995+K:1996 / granulometric composition / LST 1419.1 / 2+
hydrophobic behaviour / LST 1419.1
1.7 / Unbound mixtures: / LST EN 13285:2010 / granulometric composition / LST EN 933-1
- for crushed stone and gravel base layers / mineral dust (fines) content / LST EN 933-1 / 2+
- for protective freeze-thaw resistant layers / largest fraction (oversize) / LST EN 933-1 / 4
- for frost-insensitive material layers, base layers prepared by way of road regeneration, road cover layers without binders / water permeability (if declared) / LST CEN ISO/TS 17892-11
1.8 / Aggregates for unbound and hydraulically bound / LST EN 13242:2003+A1:2008(D) / indicators specified in the standard according to intended use of products / LST EN 13242:2003+A1:2008
materials:
- for crushed stone and gravel base layers / 2+
- for protective freeze-thaw resistant layers / 4
for frost-insensitive material layers, base layers prepared by way of road regeneration, road cover layers without binders
1.9 / Aggregates for railway ballast: / LST EN 13450:2003(D) / indicators specified in the standard according to intended use of products / LST EN 13450
- Common network and enterprise access roads / LST EN 13450:2003/AC:2004(D) / 2+
- For enterprise internal roads / 4
2. / BINDING MATERIALS
2.1 / common cement (all types) / LST EN 197-1:2001(D) / indicators specified in the standard according to intended use of the product / LST EN 196-1,-2,-3,-8,-9 / 1+
CEM I, CEM II, CEM IV, CEM V / LST EN 197-1:2001/A1:2004(D) / content of alkali (unit value not exceeding 0,8%) ***
CEM III/A / LST EN 197-1:2001/A3:2007(D) / content of alkali (unit value not exceeding 1,1%) ***
CEM III/B and CEM III/C / content of alkali (unit value not exceeding 2%) ***
2.2 / blast furnace cement of low early strength / LST EN 197-4:2005(D) / indicators specified in the standard according to intended use of the product / LST EN 196-1, LST EN 196-2, LST EN 196-3 / 1+
2.3 / sulphate-resistant blast furnace cement / LST EN 197-1:2001(D) and LST L 1970:2004 / indicators specified in the standard according to intended use of the product / LST EN 196-1, LST EN 196-3, LST EN 196-6 / 1+
2.4 / masonry cement / LST EN 413-1:2004(D) / indicators specified in the standard according to intended use of products / LST EN 413-2, LST EN 196-1 / 1+
LST EN 196-2, LST EN 196-3
2.5 / special low heat cements / LST EN 14216:2004(D) / indicators specified in the standard according to intended use of products / LST EN 196-1, LST EN 196-2, LST EN 196-3 / 1+
LST EN 196-5, LST EN 196-9
2.6 / building limes / LST EN 459-1:2010(D)(2012-06-01) / indicators specified in the standard according to intended use of products / LST EN 459-2 / 2+
2.7 / calcium aluminous cement / LST EN 14647:2006(D) / indicators specified in the standard according to intended use of products / LST EN 14647 / 1+
LST EN 14647:2006/AC:2006(D)
2.8 / sulphate cement / LST EN 15743:2010(D)(2011-11-01) / indicators specified in the standard according to intended use of products / LST EN 15743 / 1+
3. / CONCRETES AND MORTARS
3.1 / construction mortars, except lime mortars: / LST L 1346:2005 / compressive strength / LST EN 1015-11
- for the mounting of structures / resistance to cold (if declared) / LST L 1413.11 / 2+
- for filling of openings, levelling of surfaces / 4
3.2 / rendering/plastering mortars / LST EN 998-1:2010(D)(2012-06-01) / indicators specified in the standard according to intended use of products / LST EN 998-1 / 4
rendering and plastering based on organic binders / LST EN 15824:2009(D) / indicators specified in the standard according to intended use of products / LST EN 15824 / 1, 3, 4
3.3 / masonry mortars / LST EN 998-2:2010(D)(2012-06-01) / indicators specified in the standard according to intended use of products / LST EN 998-2 / 2+, 4
3.4 / gypsum block binder / LST EN 12860+AC:2002(D) / indicators specified in the standard according to intended use of products / LST EN 12860+AC / 3, 4
3.5 / floor levelling materials / LST EN 13813:2003(D) / indicators specified in the standard according to intended use of products / LST EN 13813, / 1, 3, 4
LST EN 13454-1:2004(D) / LST EN 13454-1
3.6 / grouts / LST EN 447:2008 / indicators specified in the standard according to intended use of products / LST EN 447 / 1+
special mortars (heat insulation, heat resistant, finish) / technical specification which the conformity is declared for / compressive strength (for heat-insulating, heat-resistant) / LST EN 1015-11
approval / strength of adherence to the base (for heat-insulating, / LST EN 1015-12, LST EN 1348
heat-resistant, finish)
density (for heat-insulating) / LST EN 1015-10
thermal conductivity coefficient (for heat-insulating) / LST EN 1745
temperature of use (for heat-resistant) / declared methods
3.7 / gypsum binders and gypsum plasters / LST EN 13279-1:2008(D) / indicators specified in the standard according to intended use of products / LST EN 13279-1 / 3, 4
3.8 / tile adhesive / LST EN 12004:2007(D) / indicators specified in the standard according to intended use of products / LST EN 12004:2007 / 3
3.9 / fresh concrete and concrete / LST EN 206-1:2002 / density / LST EN 12390-7 / 1+
(with heavy, light and porous aggregates) / LST EN 206-1:2002/A1:2004 / compressive strength / LST EN 12390-3
LST EN 206-1:2002/A2:2005 / consistency of mixture / LST EN 12350-2, LST EN 12350-3,
LST 1974:2005 / LST EN 12350-4, LST EN 12350-5
LST 1974:2005/1K:2010 / resistance to cold (if declared) / LST L 1428.17, LST 1428.19
water non-permeability (if declared) / LST EN 12390-8, LST 1974
3.10 / road cover surface dressing / LST EN 12271:2007(D) / indicators specified in the standard according to intended use of products / LST EN 12271 / 2+
3.11 / asphalt concrete / LST EN 13108-1:2006(D) / indicators specified in the standard according to intended use of products / LST EN 13108-1 / 2+
LST EN 13108-1:2006/AC:2008(D)
3.12 / very thin layer asphalt concrete / LST EN 13108-2:2006(D) / indicators specified in the standard according to intended use of products / LST EN 13108-2 / 2+
LST EN 13108-2:2006/AC:2008(D)
3.13 / soft asphalt / LST EN 13108-3:2006(D) / indicators specified in the standard according to intended use of products / LST EN 13108-3 / 2+
LST EN 13108-3:2006/AC:2008(D)
3.14 / hot rolling asphalt / LST EN 13108-4:2006(D) / indicators specified in the standard according to intended use of products / LST EN 13108-4 / 2+
LST EN 13108-4:2006/AC:2008(D)
3.15 / gravel and mastic asphalt / LST EN 13108-5:2006(D) / indicators specified in the standard according to intended use of products / LST EN 13108-5 / 2+
LST EN 13108-5:2006/AC:2008(D)
3.16 / mastic asphalt / LST EN 13108-6:2006(D) / indicators specified in the standard according to intended use of products / LST EN 13108-6 / 2+
LST EN 13108-6:2006/AC:2008(D)
3.17 / porous asphalt / LST EN 13108-7:2006(D) / indicators specified in the standard according to intended use of products / LST EN 13108-7 / 2+
LST EN 13108-7:2006/AC:2008(D)
3.18 / slurry surfacing / LST EN 12273:2008(D) / indicators specified in the standard according to intended use of products / LST EN 12273 / 2+
3.19 / admixtures for concrete / LST EN 934-2:2009(D) / indicators specified in the standard according to intended use of products / LST EN 934-2 / 2+
3.20 / masonry mortar admixtures / LST EN 934-3:2010(D) / indicators specified in the standard according to intended use of products / LST EN 934-3 / 2+
3.21 / additives for pre-stressed reinforcement channel grout / LST EN 934-4:2009(D) / indicators specified in the standard according to intended use of products / LST EN 934-4 / 2+
3.22 / grout additives. Torcrete concrete admixtures / LST EN 934-5:2008(D) / indicators specified in the standard according to intended use of products / LST EN 934-5 / 2+
3.23 / protection and repair products and systems for concrete structures. / LST EN 1504-2:2004(D) / indicators specified in the standard according to intended use of products / LST EN 1504-2 / 1, 2+, 3, 4
Concrete surface protection systems
3.24 / protection and repair products and systems for concrete structures. / LST EN 1504-3:2006(D) / indicators specified in the standard according to intended use of products / LST EN 1504-3 / 1, 2+, 3, 4
Structural and non-structural repair
3.25 / protection and repair products and systems for concrete structures. / LST EN 1504-4:2005(D) / indicators specified in the standard according to intended use of products / LST EN 1504-4 / 1, 2+, 3, 4
Structural adhesives
3.26 / protection and repair products and systems for concrete structures. / LST EN 1504-5:2005(D) / indicators specified in the standard according to intended use of products / LST EN 1504-5 / 2+ , 4
Concrete grouting
3.27 / protection and repair products and systems for concrete structures. / LST EN 1504-6:2007(D) / indicators specified in the standard according to intended use of products / LST EN 1504-6 / 1, 2+, 3, 4
Reinforcing bar anchoring
3.28 / protection and repair products and systems for concrete structures. / LST EN 1504-7:2007(D) / indicators specified in the standard according to intended use of products / LST EN 1504-7 / 2+, 4
Reinforcement protection against corrosion
3.29 / fly ash for concrete / LST EN 450-1:2005+A1:2008(D) / indicators specified in the standard according to intended use of products / LST EN 450 / 1+
3.30 / silica micro-dust for concrete / LST EN 13263-1:2005(D) / indicators specified in the standard according to intended use of products / LST EN 13263-1 / 1+
LST EN 13263-1:2005+A1:2009(D)
3.31 / Gypsum-based adhesive for thermal insulation and (or) acoustic insulation composite panels and dry plaster panels / LST EN 14496:2005(D) / indicators specified in the standard according to intended use of products / LST EN 14496 / 3, 4
3.32 / ground granulated blast furnace slag used in concrete, mortar and grout / LST EN 15167-1:2007(D) / indicators specified in the standard according to intended use of products / LST EN 15166 / 1+
4. / MASONRY UNITS AND ANCILLARY ELEMENTS
4.1 / clay masonry units / LST EN 771-1:2003(D) / indicators specified in the standard according to intended use of products and / LST EN 771-1 / 2+