PF Bosman
Fax
To: / Legadima Personnel / From: / Petru BosmanFax: / 012 366 0098 / Date: / October 10, 2002
Phone: / Pages: / 9
Re: / Ref #683 Project / SystemsEngineer / CC:
Urgent For Review Please Comment Please Reply Please Recycle
•Comments:
Included please find my CV for the application of the position for Project / Systems Engineer as advertised Ref #683.
Regards
Petru Bosman
CURRICULUM VITAE
Petru Francois Bosman
P.O. Box 1413
Standerton
2430
South Africa
+27 017 7495871 (W) +27 017 7140293 (H) 0823764640 (cell)
Requested Title:
PLC/HMI Programmer or C&I Systems Engineer.
Present Employer:
ESKOM Tutuka Power Station.
Position 5:
Position:System Engineer
Department:C&I Engineering
Period: Jan 1999 to present (4 years)
Company: ESKOM Tutuka Power Station
Experience:
- Siemens S7 PLC hardware configuration, programming, HMI interfacing and commissioning.
- Siemens WinCC SCADA configuration and graphic design
- Siemens OP 37 (Operating Panel) Programming and PLC interface
- Management of budgets and projects allocated on the Station’s C&I Technical Plan
- Life cycle planning of C&I equipment
- C&I modification or upgrade feasibility study, design, budget execution and implementation.
- Investigations into Plant failures and new designs for control system replacement.
- Drafting and implementing procedure for operating and maintenance.
- Verifying modifications and recommendations of setting adjustments to the C&I equipment.
Responsibilities:
- Water Treatment Plant process control efficiency and life cycle planning.
- Station Process computer network Administration.
- Station PLC programming and software administrator with regarding to modifications.
- Involved with compiling a scope of work regarding PLC / Teleperm C replacement with DCS and drafting HMI specifications for future C&I plant refurbishment.
Position 4:
Position: Senior Instrument Technician
Department:C&I Maintenance dept.
Period: 01/03/1994 to Jan 1999 (5 year)
Company: ESKOM Tutuka Power Station
Experience:
- Siemens S5 (115U/150) PLC fault finding and modifications program design and implementation.
- Boiler Control system optimisation (consisting predominantly of Teleperm C), fault finding and monitoring.
Responsibilities:
- Efficient and optimum Auto Control of the Power Station Boilers and Boiler Auxiliaries.
- Work in close liaison with Production Managers, Performance and Monitoring and Engineering to present conclusions from tests and analysis of Plant faults.
- Attend ESKOM Optimization Forums; Optimization methods and unresolved problems are presented by all Stations. The Forum is chaired by a Senior Engineer from Head office and attended by Engineers and Optimization Specialists from the relevant Power Stations.
Position 3:
Position: Instrument Technician
Department:C&I Maintenance dept.
Period: 01/07/1987 to 30/06/1994 (7 year)
Company: ESKOM Tutuka Power Station (Water Treatment Plant)
Experience:
- Siemens S5150 PLC maintenance, fault finding and modification implementation.
- Siemens Teleperm C and Iskamatic B maintenance, fault finding and modification implementation
- Field instrumentation maintenance and calibration such as PH, conductivity, chlorine and turbidity analysers. Flow, pressure and level transmitters which include ultrasonic, radar and magnetic primary measuring principles.
Responsibilities:
- Maintenance of the Water Treatment Plant Control and Instrumentation.
- Required being on standby for C&I related emergency breakdowns on the Station, after hours, one week per two months.
Position 2:
Position: Instrument Mechanician
Department:C&I Maintenance dept.
Period: 27/12/1985 to 30/06/1987 (2 year)
Company: ESKOM Tutuka Power Station (Coal and Ash Disposal Plant)
Experience:
- Calibration and Maintenance, on Coal Silos and Ash Bunkers field Instrumentation. Which included Nuclear level switches, Capacitance Level Transmitters, and strain-Gauge Level Transmitters.
- Calibration and Maintenance on Condensate Polishing Plant, Low Pressure Diesel/Electrical Compressors, Cooling Water Plant, and Ash disposal Plant field Instrumentation. Which included RTD Temperature Transducers, Bearing Vibration Transducers, Proxcimitry switches, Analyzers and Control Valves.
- Program, Debugging and Hardware Faultfinding using the applicable Programming Units on S5-Siemens, AEG and Modicon PLCs.
- Step 5 150 PLC maintenance and fault finding
- Maintenance of Texas Instrument PLC at Majuba Power Station temporary Potable Water Treatment plant (No C & I Personnel were yet established).
Responsibilities:
- Calibration, Maintenance and routine inspections on Coal/Ash conveyor field Instrumentation. Which included Misalignment Switches, Belt-Rip Switches, Speed Switches, Block Shut Switches and belt Tension Controllers.
Position 1:
The four-year apprenticeship served was fairly equally divided in stages of college semesters, internal ESKOM courses and on-job training. I finally completed the relevant Trade test preparation courses and qualified as an Instrument Mechanician on 27/12/1985 after I passed the said trade test at Olifantsfontein (Department of Manpower Trade Test Central Organization).
Position: Apprentice Instrument Mechanician
Department:C&I Maintenance dept.
Period: 08/01/1982 to 27/12/1985 (4 years)
Company: ESKOM Kriel Power Station
Qualifications obtained:
National N6 Diploma (01/05/1984)
Experience:
- Maintenance and calibration of Kent field instrumentation at the Water Treatment Plant namely: DP flow Transmitters, Pressure Transmitters, Flow Integrators, Flow Switches, paper Recorders and Sodium, Oxygen, pH Analysers.
- Fault finding on Relay Logic Interlock Pump Stations.
- Testing and maintenance on RTD temperature Measurement.
- Stroking of Pneumatic and electrical Actuators and Control Valves. Calibration of Pneumatic Positioners.
- Specialised in maintaining and fault finding on a CMOS Conlog system used for sequential step control of De-mineralised water production and Resin cleaning.
Qualifications:
NATIONAL N6 DIPLOMA IN RESPECT OF THE FOLLOWING:
Subjects:Electronics (Distinction)
Control Systems
Digital Electronics (Distinction)
Industrial Instruments (Distinction)
Electrotechnics
Mathematics
Mechanotechnics
Power Machines
Strengths of Materials
MICROSOFT CERTIFIED SYSTEMS ENGINEER:
Subjects:Microsoft NT4.0 Workstation
Microsoft NT4.0 Server
Microsoft NT4.0 Server Enterprises
Network Essentials
TCP/IP on Microsoft
Microsoft SQL Server 7.0
ESKOM Internal and external causes:
Subjects:Win CC (Siemens)
S7 PLC programming (Siemens)
S5 Siemens PLCs
Siemens Teleperm C
In Touch SCADA
Microprocessors (Practical)
Protuner
Electronics (Practical)
Digital Electronics (Practical)
Fault Finding (Practical)
Reference:
Johan Visagie (C&I Engineering Manager ESKOM Tutuka Power station)
+27 017 7499219 (W)
Carel Stoop (C&I Maintenance Manager ESKOM Tutuka Power station)
+27 017 7495709 (W)
Date and Place of Birth:
March 27 1962, Gweru, Zimbabwe
Nationality:
South African
Language:
Spoken and Written English
Marital Status:
Divorced with two children
State of Health:
Good
1