BEKA LEDshine

Technical Product Specifications

Table of contents

1. General Specifications 3

2. Photometry 3

3. Mechanics 4

4. Electrical Characteristics 5

5. Environment 5

6. Version specific characteristics 5

7. Certification and Compliance to Standards 6

8. Storage Conditions 7

1.  General Specifications

Product Description / Modern LED post top luminaire designed for general area lighting where good optical control is required in conjunction with modern architecture.
Main applications / Class B road Lighting, Parking Areas, General Area Lighting, Parks and Gardens.
Recommended mounting height / 3.5m – 5m

2.  Photometry

Light source / LED
Number of LED / 36
LED / OSRAM
Light color / Neutral White (4000K)
Color rendering (Ra) / >70
Lumen package
36 LED / 3850
Optics / LEDshine 43W-Louvre
Photometry: / See Photometric Tables

Protector / High Impact Acrylic (IK07)

3.  Mechanics

Electronic Control Gear / Constant Current Driver Osram OT45
Materials and Finishing / Painted Aluminum Housing – Standard Grey (RAL 7045)
Coating / RAL colours on request
Installation / Pole Mount or Wall Mount
Fixing / 3x
Dimensions (DxH) / 245mm x 565mm
Weight (with gear) / 10kg
Windage Area CxS / 0.19m2
Access / Yes

4.  Electrical Characteristics

Line Voltage / 230VAC
Mains Voltage Tolerance (AC) / 207-253V
Line Frequency / 50Hz
Electrical Safety Class (IEC) / I
Surge Protection / N/A
Lighting Regulation / N/A

5.  Environment

Storage Temperature / -40oC< T < 85oC
Enclosure Tightness / IP 65 Gear and Optical
Enclosure Mechanical Withstand Impact / IK07 (Acrylic)

6.  Version specific characteristics

Luminaire configuration:

LED Lumen Depreciation
@ Tq = 25°C @ 60.000hrs @350mA / ≤20%
Typical Input Power @ Ta = 25°C / Max. 43W
Power Factor (not dimmed) / >0.9
THD / <20%
Operating Temperature Range (Safety - no damage) (*) / -20 oC < Ta <35 oC
Operating Temperature for Performance and Lifetime (L80@60000h) (*) / Tq max = 35 oC
LED Junction Temperature @ Tq max.
/ <85oC

7.  Certification and Compliance to Standards

Electrical Safety / SANS 60598-2-3
EMC-EMI / Immunity: SANS61547
Electrostatic Discharges:
SANS61000-4-2
Radiated Fields: SANS61000-4-3
Fast Transient Burst: SANS61000-4-4
Surges: SANS61000-4-5
RF Conducted Perturbations: SANS61000-4-6
Main Magnetic Fields: SANS61000-4-8
Voltage Dips: SANS61000-4-11
Emission:
Radiated Emissions: SANS55015
Conducted Emissions: SANS55015
Harmonics: SANS61000-3-2
Flicker: SANS61000-3-3
Impact Test / SANS 62262
Enclosure Protection Level / SANS 60529

8.  Storage Conditions

Until installation, luminaires should be placed in a covered dry storage area, preferably in a roofed area with a tarp keeping water off the cardboard boxes, and protected against marine salt environment.
Prior to installation, luminaires should not be stored outside in cardboard boxes alone.
Maximum storage temperature: + 85°C with relative humidity up to 95% no condensing.
Minimum storage temperature: - 40°C
Exposure to extreme conditions cannot exceed 6 months.
After installation, the luminaire may not stay unpowered over 12 months while exposed to extreme conditions described here above.
These storage conditions refer to best industrial practices in compliance with what is required by our suppliers, leaders in their fields.
Written by / Approved by / Document Revision / Date
Mathew Wolmarans / Daniel Kasper / 2017-02-24

(*) For specific Tq, Ta and lifetime data, contact BEKA Schréder