Method 4: Nitrate as Nitrogen with Spectrophotometer, HACH DR 2010/2000
Method 8171
Purpose/Objectives :
To measure the nitrate ion concentration in water samples while in the field or in the lab. Samples are analyzed using a HACH spectrophotometer. The instrument uses a stored calibration curve, requiring only a reagent blank. Data is reported as mg/L NO3-1-N.
Equipment and Materials
- HACH DR 2010/2000CBL System
- deionozed water
- 25 mL matched cells
- HACH NitroVer 5 Nitrate Reagent Powder Pillows
- cell stopper
Sample Collection and Preservation
1.25 mLs of water sample is required for each analysis.
2.To obtain a representative sample:
- Collect sample from below surface of water.
- Sample from as far away from shore as is safe. Use a sampling device made of a rod and container if necessary.
3.Samples held for off-site testing within a few hours should be refrigerated.
Safety Alert:
1.HACH NitroVer 5 Nitrate Reagent Powder Pillows contain the heavy metal cadmium, a known carcinogen; extremely toxic by inhalation of dust or fumes.
2.Use extreme care when handling this reagent!
Analysis Procedure
1.Enter the stored program number “353” for medium range NO3-1-N. Press ENTER.
2.Rotate wavelength dial to 400 nm. The display should prompt to “Zero Sample.” Then display will read “mg/L NO3-1-N.”
3.Fill sample cell with 25 mL of sample. Fill another sample cell with 25 mL of deionized water.
4.Add contents of 1 NitroVer 5 Nitrate Reagent Powder Pillow to each cell. Stopper.
5.Press SHIFT TIMER . A one minute reaction time will begin. Shake until timer beeps.
6.When timer beeps press SHIFT TIMER . a five minute reaction timewill begin.
7.When timer beeps, display will show “mg/L NO3-1-N.” Remove stopper from blank; place blank into cell holder; close light shield.
8.Press ZERO. the display will show “Zeroing…” then it will show
“0.0 mg/L NO3-1-N.”
9.Remove blank and replace with cell of prepared sample. Close light shield.
10. Press READ. The display will show “Reading…”, then the result as mg/L NO3-1-N.
11.Record concentration values to the nearest 0.1 mg/L NO3-1-N on Data and Calculations Log Sheet.
Waste Disposal
1.Dispose of waste as instructed by supervisor.
References
WaterAnalysisHandbook, 3rd Edition, HACH Company, Loveland, Colorado, 1997.
DATA AND CALCULATIONS LOG SHEET
Method 2: Nitrate-Colorimeter with Multiple Standards
Student Team:______Hour:______
Student Name:______
Student Name:______
Student Name:______
Stream or lake sampled:______Sample Date:______
Site Name:______Sample Time:______
Site Number:______Sampled By:______
Column /A
Reading / NO3-1-N(mg/L)
1
2
Average Nitrate (mg/L NO3-1-N)
Column Procedure:
A.Record NO3-1-N concentration as direct reading from instrument. MDL = 0.1 mg/L NO3-1-N Linear range = 0 – 4.5 mg/L NO3-1-N
Field Observations:
______
Analysis Date:______Analysis Time:______
Analysts:______