DOCUMENTATION HANDED OVER
Goods lift data to be transcribed in the use and maintenance manual:
- Good lift name______
- Model:______
- Serial number:______
- Year of construction:______
ATTACHMENTS
Declaration of conformityObligations of the owner, obligations of the employer,
Good lift manual
User manual
Maintenance manual
Installation manual
Aluminium identification plates
Updinamic S.r.l.
Please return this sheet countersigned as confirmation of receipt of the documents via fax number 0442-599091 or via e-mail to
SIGNATURE FOR RECEIPT(customer)
______
Pagina 1 di 14
DECLARATION OF COMPLIANCE
The company UPDINAMIC S.r.l., which operates in the automatic parking sector, with its registered offices in : via Modigliani, 22 – 37045 – Legnago (VR) -ITALY, entrolled in the records of the Chamber of Commerce of Verona and tax number 03584130235. Enrolled at the EARegister.. 348256
THE LATTER DECLARES UNDER HIS OWN RESPONSIBILITY THAT THE NEW MACHINE
-called ______
-mod, ______
-registration number ______
built during the year ______
Operation mode: apparatus for goods-lifting only, with fixed carrying capacity, connecting the various floors with vertical movement on rigid guides.
start up and complaints to compliant with the needs imposed by the following EC Directives:
- Machinery Directive 2006/42/CE;
- CEE 89/106 Directive on construction products;
- Directive 89/336/CEE
Reference was made to harmonised laws during planning, in particular:
- standards UNI EN ISO 12100 part I – II; UNI 14010 ; UNI EN ISO 1387:2008 EN 349; EN 60204-1;
It is also declared that::
- Pursuant to the Machinery Directives 2006/42/CE “the technical file of the machine, together with attachment VII is available at the manufacturer’s site and the updating manager is Mr. Oscar Donà.
It should be noted that the machine cannot be put into service until it is established to comply with all applicable rules and regulations in the country of installation.
Legnago, date ______/______/______,
UPDINAMIC S.r.l.
Via Modigliani 22
Legnago (VR) -Italy
The sole administrator
(Albino Donà)
DECLARATION OF COMPLIANCE
UPDINAMIC s.r.l.
Via Modigliani , 22
37045 LEGNAGO (VR)
GOOD LIFT MANUAL
MODEL UP__
(designed to carry goods only)
INSTALLED IN THE BUILDING OWNED BY:
______IN______N°______
MUNICIPALITY______
MODEL______
SERIAL NO.______
OWNER’S LEGAL REPRESENTATIVE: ______
ANY SUBSEQUENT CHANGES IN SYSTEM OWNERSHIP:
______
THIS MANUAL MUST BE KEPT BY THE OWNER IN THE TECHNICAL CABINET TOGETHER WITH THE ATTACHMENTS LISTED BELOW:
GOOD LIFT MANUAL
USER MANUAL
ELECTRICAL PART MANUAL
MAINTENANCE MANUAL
Pagina 1 di 14
GOOD LIFT MANUAL
Pagina 1 di 14
The good lift has been constructed in compliance with the following directives:
MACHINE DIRECTIVE 2006/42/EC
ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89/336/EEC AND RELATIVE AMENDMENTS
LOW VOLTAGE DIRECTIVE 73/23/EEC
The good lift is hence supplied complete with the documentation as required by these directives.
The good lift has been designed to guarantee safe conditions of use. Deactivating and removing the electrical and other safety devices installed by the manufacturer will seriously jeopardise good lift safety. Proper use moreover requires strictly following the instructions for installation, power supply and maintenance of the good lift.
The good lift must be used according to the intended use specified by the manufacturer in the user manual that accompanies this manual: it is therefore advisable to carefully read this manual before transport, installation and startup of the good lift.
Maintenance consists of a few simple operations that can be carried out by a qualified operator who meets the requirements established by law. In order to get the longest life and the most cost-effective operation out of the good lift, it is advisable to strictly follow the instructions contained in this document and in the accompanying manuals.
The manufacturer cannot be held responsible for breakage, accidents or other problems due to inobservance (or in any case failing to apply) the rules contained in this manual, the user manual and the maintenance manual. The same is true for making modifications, variations or installation of unauthorised accessories.
This manual, the user manual and the maintenance manual form an integral part of the good lift: it is essential that they be kept intact in the technical cabinet of the good lift so that they are easily accessible for the entire lifetime of the goodlift, even in the event of the good lift passing to another user. They must also be easily and readily accessible for consultation by the operators and the maintenance technicians and must therefore be kept close to the equipment.
CAREFULLY READ AND KEEP THIS MANUAL, THE USER MANUAL AND THE MAINTENANCE MANUAL.
SHOULD YOU REQUIRE COPIES OR UPDATES OF THE MANUALS, PLEASE CONTACT:
UPDINAMIC S.r.l. Via Modigliani 22, 37045 Legnago VR (ITALY)
Tel. 0442-590129 – Fax 0442-599091 – E-mail
GOODLIFT DESCRIPTION
Electro-hydraulic vertical goods lift designed for the transportation of goods to various underground or above-ground levels with a travel of up to 12 metres. UP has a wall-mounted load-bearing structure constructed of special structural steel beams in which combined bearings slide. The platform is driven by a hydraulic cylinder with double-chain transmission.
Model / Carrying capacityKg
UP 3 / 300
UP 6 / 600
UP 10 / 1000
UP 15 / 1500
UP 20 / 2000
UP 25 / 2500
GENERAL
Model:
UP3UP6 UP10 UP15 UP20 UP25
Serial number:
Year of installation:
2011 20122013 2014 2015
Carrying capacity [kg]:
300 600 1000 1500 2000 2500
Travel [mm]:
Speed [m/s]:
Levels served:
23 4
Accesses:
1 accesso 2 accessi3 accessi
Platform dimension [mm]:
Standard: Length. 900mm; Width. 1300mm
Customised: Length: ______Width: ______
EXTERNAL SAFETY DEVICES AND COMPONENTS
Safety devices on ground level:
Gate or door with external electric lock
Door with integrated electric lock
Other______
Safety devices on other levela:
Gate or door with external electric lock
Door with integrated electric lock
Other ______
Control:
No. of pushbutton panels: ______
Deadman pushbutton panel
Pulse-operated pushbutton panel
TECHNICAL CABINET
Position on ground level:
0 -1 ______
Maximum distance from the lift shaft: 6 m
Environment:
Closed Protected ______
Technical cabinet dimensions:
Width: ______Depth: ______Height: ______
Access:
DirectIndirect through common rooms/property
Lighting:
Lighting in proximity of the control unit: ______LUX [≥200LUX]
Lighting in proximity of the electric cabinet ______LUX [≥200LUX]
Type of ventilation openings:
Cabinet vents towards a ventilated room and connected to the outside
Vent in the cabinet and connection tube to the outside
System according to the fire-fighting requirements
MOTOR AND ELECTRIC CIRCUIT
Standard components (BASIC outfitting):
Onboard the good:
Good lift levelmechanical limit switch
Platform positioning Mechanical limit switch
n.2 Proximity Safety hook ceck
Circuit board
External components:
Call buttons
Emergency stop button
Led onbuttons
Technical cabinet:
Up solenoid valve
Down solenoid valve
Optional components:
External components:
Exsternal electric lock
Standard doors
Doors with Kronemberg integrated electric lock
Emergency descent components
Onboard the good lift:
Emergency descent solenoid valve
HYDRAULIC SYSTEM
Gear pump:
Flow rate ______cc/g
Hydraulic oil/fluid type W.Engine HySy 22/B:
Density at 15°: 0.858 kg/l
cSt viscosity at 40°C: 23.8
Englar viscosity at 50°C: 2.3
Viscosity index: 105
Pour point: -33°C
VA flammability: 192°C
Aniline point: 96
DIN 51 524 HLP classification: 22
Maximum pressure: 160 bar
Suspension devices:
UP3
1 hydraulic cylinder with rigid tubes to a safety check valve
Rexroth VEI-8A-2A-06-NC-S-M
1chain type Flayer AL644 19.05mm Sedis, traction breakage 80 kN
UP6
1 hydraulic cylinder with rigid tubes to a safety check valve
Rexroth VEI-8A-2A-06-NC-S-M
1 chain type Flayer AL644 19.05mm Sedis, traction breakage 80 kN
UP10
1 hydraulic cylinder with rigid tubes to a safety check valve
Rexroth VEI-8A-2A-06-NC-S-M
2 chains type FlayerAL644 19.05mm Sedistraction breakage 80 kN
UP15
1 hydraulic cylinder with rigid tubes to a safety check valve
Rexroth VEI-8A-2A-06-NC-S-M
2 chains type Flayer AL644 19.05mm Sedistraction breakage 80 kN
UP20
1 1 hydraulic cylinder with rigid tubes to a safety check valve
Rexroth VEI-8A-2A-06-NC-S-M
2 chains type FlayerAL666 19.05mm Sedistraction breakage 115.8 kN
UP25
1hydraulic cylinder with rigid tubes to a safety check valve
Rexroth VEI-8A-2A-06-NC-S-M
2 chains type Flayer AL666 19.05mm Sedistraction breakage 115.8 kN
LIFT SHAFT
Reinforced concrete construction
Lift shaft dimensions [mm]:
Standard: Length. 1060mm; Width. 1360mm
Customised: Length: ______Width: ______
Maximum difference in height between levels [mm]:
Standard: 3000
Customised: ______
SAFETY DEVICES INSTALLED
UP3 e UP6 MODELS
Check valves
Rexroth VEI-8A-2A-06-NC-S-M
Maximum press: 350 bar
Maximum flow rate: 40 l/min
Electric drive: elettrico 24V DC
Ceck: proximity
Parachute valve
Rexroth VPN-OT.F4.01-03-02– valve against tube breakage
Mechanical safety hooks
Hydraulic device integrated in the goods lift system and controlled by proximity.
UP10 UP15 UP20 UP25 MODELS
Doble lift chain
Valvole di blocco
Rexroth VEI-8A-2A-06-NC-S-M
Maximum press: 350 bar
Maximum flow rate: 40 l/min
Electric drive: elettrico 24V DC
Ceck: proximity
Parachute valve
Rexroth VPN-OT.F4.01-03-02– valve against tube breakage
Mechanical safety hooks
Hydraulic device integrated in the goods lift system and controlled by 2 proximity.
GENERIC SAFETY DEVICES FOR ALL MODELS
Electric locks:
Pizzato FS2896D024-F
Degree of protection: IP66
Operating temperature: -25°C to 60°C
Voltage: 24VDC
Absorption: 1A
Mechanical life: 800,000 cycles
Retention force: 1100 N
Extraction force: 30 N
Pagina 1 di 14