Display Hidden Notes to Specifier. (Don't Know How? Click Here) s85

SECTION 09 91 00

PAINTS

Display hidden notes to specifier. (Don't know how? Click Here)

Copyright 2005 - 2016 ARCAT, Inc. - All rights reserved

** NOTE TO SPECIFIER ** Kelly-Moore Paints; paint and coating products.
.
This section is based on the products of Kelly-Moore Paints, which is located at:
987 Commercial St.
San Carlos, CA 94070
Toll Free Tel: 888-MR PAINT
Tel: 888-kmcolor
Fax: 650-592-1215
Email: request info ()
Web: www.kellymoore.com
[ Click Here ] for additional information.
ACRY-PLEX: Premium interior primers and finishes, formulated with 100 percent acrylic technology, providing excellent adhesion and durability for all types of construction applications.
ENVIRO-COAT: Premium interior primers and finishes providing low VOC and low odor, excellent for application in schools, health care, office, hospitality, and institutional facilities.
PREMIUM PROFESSIONAL: Professional interior primers and finishes providing low VOC and low odor, durability, good practical hide, and touch-up, designed for all types of construction applications.
ACRY-SHIELD: Premium exterior primers and finishes, formulated with 100 percent acrylic technology, providing excellent adhesion and durability for all types of construction applications.
PREMIUM PROFESSIONAL: Professional exterior primers and finishes, providing good durability, adhesion, and touch-up, suitable for all types of construction applications.
DURA-POXY +: High performance interior/exterior finishes with excellent adhesion, formulated to produce an epoxy-like film for durability and stands up to repeated scrubbing. Excellent for construction applications in high traffic areas.
KEL-SEAL: A selection of premium products that include sealants, elastomeric wall coatings, and silane emulsions to prevent water intrusion or water migration through the substrate.
ELASTAKOTE: A professional quality elastomeric wall coating, providing good film strength, integrity, and elongation. Designed to bridge hairline cracks and help prevent moisture penetration for masonry/concrete substrates.
KEL-TEX: A premium high build, acrylic texture coating, formulated to color coat and texture in one operation on new or existing masonry/concrete substrates.
KEL-GUARD: Premium rust preventative, alkyd primers and finishes providing excellent durability and adhesion, designed to prevent corrosion on metal substrates.
DTM: High performance acrylic primers and finishes providing excellent adhesion, durability, and color retention designed for light industrial applications.
KEL-BOND Universal Primer: An all purpose primer, sealer and stain killer providing excellent adhesion to hard, dense surfaces, such as metal, glass, tile, plastic laminates, etc. Excellent for a wide range of substrates.
KEL-THANE II: Premium interior acrylic/urethane clear coatings designed for all types of wood surfaces. Features include low odor, non-yellowing, and abrasion resistance properties.
E-COAT: Recycled paint made with a minimum of 50 percent post consumer paint. Re-manufactured to insure good durability for interior or exterior applications.
See our SpecWizard: Click Here

1 GENERAL

1.1   SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

1.1.1   Surface preparation and field painting of exposed interior items and surfaces, including mechanical and electrical equipment that do not have a factory-applied finish.

1.1.2   Surface preparation and field painting of exposed exterior items and surfaces.

1.2   RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

1.2.1   Section 03 30 00 - Cast-in-Place Concrete: Surface coordination and curing provisions.

1.2.2   Section 05 12 00 - Structural Steel Framing: Shop priming structural steel.

1.2.3   Section 05 50 00 - Metal Fabrications: Shop priming ferrous metal.

1.2.4   Section 06 20 00 - Finish Carpentry: Shop priming architectural woodwork.

1.2.5   Section 08 11 13 - Hollow Metal Doors and Frames: Factory priming steel doors and frames.

1.2.6   Section 09 21 16 - Gypsum Board Assemblies: Surface preparation of gypsum board.

1.2.7   Section 21 05 00 - Common Work Results for Fire Suppression: Mechanical identification.

1.2.8   Section 26 05 00 - Common Work Results for Electrical: Electrical identification.

1.3   REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

1.3.1   ASTM International (ASTM): ASTM D 16 - Standard Terminology for Paint, Related Coatings, Materials, and Applications.

1.3.2   Steel Structures Painting Council (SSPC) SP6 - Commercial Blast Cleaning Procedures.

1.3.3   Steel Structures Painting Council (SSPC) SP10 - Near White Blast Cleaning Procedure.

1.4   DEFINITIONS

1.4.1   General: Standard coating terms defined within Masters Painters Institute (MPI) manual.

1.4.1.1   Gloss level 1 - Flat with a gloss range below 5 when measured at a 60-degree meter and 10 when measured at an 85-degree meter.

1.4.1.2   Gloss level 2 - Low Sheen with a gloss range of 5 to 10 when measured at a 60 degree meter and 10 to 35 when measured at an 85 degree meter.

1.4.1.3   Gloss level 3 - Eggshell with a gloss range between 10 and 15 when measured at a 60-degree meter and 10 to 35 when measured at an 85-degree meter.

1.4.1.4   Gloss level 4 - Satin with a gloss range between 25 to 35 when measured with a 60 degree meter.

1.4.1.5   Gloss level 5 - Semi-Gloss with a gloss range between 50 and 55 when measured at a 60 degree meter.

1.4.1.6   Gloss level 6 - Gloss with a gloss range more than 70 when measured at a 60 degree meter.

1.5   SUBMITTALS

1.5.1   Submit under provisions of Section 01 30 00.

1.5.2   [ Product Data ]: Manufacturer's data sheets on each product to be used, including:

1.5.2.1   Material List: An inclusive list of required coating materials. Indicate each material and cross-reference specific coating, finish system, and application. Identify each material by manufacturer's catalog number and general classification.

1.5.2.2   Preparation instructions and recommendations.

1.5.2.3   Manufacturer's Information: Manufacturer's technical information, including label analysis and instructions for handling, storing, and applying each coating material.

** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.

1.5.3   Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.

1.5.4   Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.

1.6   QUALITY ASSURANCE

1.6.1   Installer Qualifications: A firm or individual experienced in applying paints and coatings similar in material, design, and extent to those indicated for this Project, whose work has resulted in applications with a record of successful in-service performance.

1.6.2   Obtain block fillers and primers for each coating system from the same manufacturer as the finish coats.

1.6.3   Paint exposed surfaces. If an item or a surface is not specifically mentioned, paint the item or surface the same as similar adjacent materials or surfaces. If a color of finish is not indicated, Architect will select from standard colors and finishes available.

1.6.4   Do not paint prefinished items, concealed surfaces, finished metal surfaces, operating parts, and labels.

** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.

1.6.5   Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.

1.6.5.1   Finish areas designated by Architect.

1.6.5.2   Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.

1.6.5.3   Refinish mock-up area as required to produce acceptable work.

1.7   DELIVERY, STORAGE, AND HANDLING

1.7.1   Deliver materials to Project site in manufacturer's original, unopened packages and containers bearing manufacturer's name and label:

1.7.2   Store materials not in use in tightly covered containers in a well-ventilated area at a minimum ambient temperature of 45 deg F (7 deg C). Maintain storage containers in a clean condition, free of foreign materials and residue.

1.7.3   Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

1.7.4   Apply waterborne paints only when temperatures of surfaces to be painted and surrounding air are between 50 and 90 deg F (10 and 32 deg C), unless manufacturers instructions specifically state's.

1.7.5   Apply solvent-thinned paints only when temperatures of surfaces to be painted and surrounding air are between 45 and 95 deg F (7 and 35 deg C).

1.7.6   Do not apply paint in snow, rain, fog, or mist; or when relative humidity exceeds 85 percent; or at temperatures less than 5 deg F (3 deg C) above the dew point; or to damp or wet surfaces.

1.7.6.1   Painting may continue during inclement weather if surfaces and areas to be painted are enclosed and heated within temperature limits specified by manufacturer during application and drying periods.

** NOTE TO SPECIFIER ** Delete if not required.

1.8   EXTRA MATERIALS

1.8.1   Furnish extra paint materials from the same production run as the materials applied and in the quantities described below. Package with protective covering for storage and identify with labels describing contents. Deliver extra materials to Owner.

1.8.2   Quantity: Furnish Owner with an additional three percent, but not less than 1 gal (3.8 l) or 1 case, as appropriate, of each material and color applied.

2 PRODUCTS

2.1   MANUFACTURERS

2.1.1   Acceptable Manufacturer: Kelly-Moore Paints, which is located at: 987 Commercial St.; San Carlos, CA 94070; Toll Free Tel: 888-MR PAINT; Tel: 888-kmcolor; Fax: 650-592-1215; Email: ; Web: www.kellymoore.com

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

2.1.2   Substitutions: Not permitted.

2.1.3   Requests for substitutions will be considered in accordance with provisions of Section 01 60 00.

2.2   PAINT MATERIALS - GENERAL

2.2.1   Material Compatibility: Provide block fillers, primers, and finish-coat materials that are compatible with one another and with the substrates indicated under conditions of service and application, as demonstrated by manufacturer based on testing and field experience.

** NOTE TO SPECIFIER ** Revise VOC rating to suit local regulations or Owner's requirements. Delete if not required.

2.2.2   VOC Classification: Provide materials, including primers, undercoats, and finish-coat materials, that meet local air quality management district regulations.

2.2.3   Color: Refer to Finish Schedule and Paint Legend for paint colors.

2.2.4   Application Rate: Coating thickness for primer, intermediate, barrier and finish coats shall be measured as Dry Film Thickness (DFT) and comply with manufacturer's published recommendations.

2.3   EXTERIOR METAL

2.3.1   Ferrous Metal:

** NOTE TO SPECIFIER ** 1710 and 1711 are alkyd base; 1725 is 100 percent acrylic latex. 5725 is a light Industrial Acrylic primer. Top coat with alkyd or acrylic finishes. Delete primer not required.

2.3.1.1   Primer:

2.3.1.1.1   1710 KEL-GUARD Alkyd Rust-Preventative Red Primer.

2.3.1.1.2   1711 KEL-GUARD Alkyd Rust-Preventative White Primer.

2.3.1.1.3   265 KM PROFESSIONAL Water - Oil Hybrid Primer/Undercoater.

2.3.1.1.4   5725 DTM Acrylic Primer/Finish.

2.3.1.1.5   1405 Devprime Alkyd Rust-Preventive Primer less than 250 gpl.

2.3.1.1.6   1403 Devprime Alkyd Rust-Preventative Primer greater than 250 gpl.

2.3.1.1.7   1440 Devcryl Acrylic Primer/Finish.

** NOTE TO SPECIFIER ** Flat finishes are not recommended for areas subject to frequent handling. Acrylic finishes provide best color and gloss retention. Best protection with two finish coats. Certain colors may require more than two finish coats. Delete finish not required.

2.3.1.2   Finish:

2.3.1.2.1   1240 ACRY-SHIELD 100 percent Acrylic Exterior Flat Finish.

2.3.1.2.2   1200 PREMIUM PROFESSIONAL 100 percent Acrylic Exterior Flat Finish.

2.3.1.2.3   1245 ACRY-SHIELD 100 percent Acrylic Exterior Low Sheen Finish.

2.3.1.2.4   1210 PREMIUM PROFESSIONAL 100 percent Acrylic Exterior Low Sheen Finish.

2.3.1.2.5   1247 ACRY-SHIELD 100 percent Acrylic Exterior Satin Finish.

2.3.1.2.6   1212 PREMIUM PROFESSIONAL 100 percent Acrylic Exterior Satin Finish.

2.3.1.2.7   1250 ACRY-SHIELD 100 percent Acrylic Exterior Semi-Gloss Enamel.

2.3.1.2.8   1215 PREMIUM PROFESSIONAL 100 percent Acrylic Exterior Semi-Gloss Enamel.

2.3.1.2.9   1700 KEL-GUARD Alkyd Rust-Preventative Gloss Enamel.

2.3.1.2.10   1920 KM PROFESSIONAL Water-Oil Hybrid Interior & Exterior Satin Enamel.

2.3.1.2.11   1930 KM PROFESSIONAL Water-Oil Hybrid Interior & Exterior Semi-Gloss Enamel.

2.3.1.2.12   1980 KM PROFESSIONAL Water - Oil Hybrid Interior & Exterior Gloss Enamel.

2.3.1.2.13   5725 DTM Acrylic Primer/Finish.

2.3.1.2.14   5885 DTM Acrylic Semi-Gloss Enamel.

2.3.1.2.15   1440 Devcryl Acrylic Primer/Finish Eggshell Sheen.

2.3.1.2.16   1449 Devcryl Acrylic Gloss Enamel.

2.3.1.2.17   1431 Devlac Gloss Alkyd Enamel.

2.3.2   Galvanized Metal, Aluminum and Copper:

** NOTE TO SPECIFIER ** Acrylic latex primer. Top coat with alkyd or acrylic finishes. Delete primer not required.

2.3.2.1   Primer:

2.3.2.1.1   5725 DTM Acrylic Primer/Finish.

2.3.2.1.2   1440 Devcryl Acrylic Primer/Finish.

** NOTE TO SPECIFIER ** Flat finishes are not recommended for areas subject to frequent handling. Acrylic finishes provide best color and gloss retention. Best protection with two finish coats. Certain colors may require more than two finish coats. Delete finish not required.

2.3.2.2   Finish:

2.3.2.2.1   1240 ACRY-SHIELD 100 percent Acrylic Exterior Flat Finish.

2.3.2.2.2   1200 PREMIUM PROFESSIONAL 100 percent Acrylic Exterior Flat Finish.

2.3.2.2.3   1245 ACRY-SHIELD 100 percent Acrylic Exterior Low Sheen Finish.

2.3.2.2.4   1210 PREMIUM PROFESSIONAL 100 percent Acrylic Exterior Low Sheen Finish.

2.3.2.2.5   1247 ACRY-SHIELD 100 percent Acrylic Exterior Satin Finish.

2.3.2.2.6   1212 PREMIUM PROFESSIONAL 100 percent Acrylic Exterior Satin Finish.

2.3.2.2.7   1250 ACRY-SHIELD 100 percent Acrylic Exterior Semi-Gloss Enamel.

2.3.2.2.8   5725 DTM Acrylic Primer/Finish.

2.3.2.2.9   5885 DTM Acrylic Semi-Gloss Enamel.