SECTION 08 33 00

COILING AND ROLLING DOORS

Display hidden notes to specifier. (Don't know how? Click Here)

Copyright 2007 - 2018 ARCAT, Inc. - All rights reserved

** NOTE TO SPECIFIER ** Raynor; commercial coiling and rolling doors.
This section is based on the products of Raynor, which is located at:
1101 East River Rd. P. O. Box 448
Dixon, IL 61021-0448
Toll Free Tel: 800-4-RAYNOR
Tel: 815-288-1431
Fax: 888-598-4790
Email:request info ()
Web:
[Click Here] for additional information.
For more than 60 years, architects and construction specifiers have counted on Raynor for doors and electric operators that meet the harshest environment and application demands. For your convenience, additional Raynor commercial specifications and drawings can be downloaded fromand are available on CD-ROM.
Raynor has more than 600 professional installing distributors in the United States and throughout 54 nations around the world. They pride themselves in excellent product knowledge, installation and service after the sale. Earn CE units and receive valuable knowledge about commercial doors by participating in an AIA/CES course. If you would like a Raynor Representative to contact you about presenting an AIA/CES course to your company, fill out an online form at, or contact us at 1-800-4-RAYNOR.
Refer to specifications in this section for the following types of Raynor Overhead Doors: Coiling and rolling doors including DuraCoil, DuraShutter, DuraGrille, FireCoil, FireShutter, FabriCoil and RapidCoil. ArmorBrite is a trademark of Tiger Drylac.

1 GENERAL

1.1 SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete types below not applicable to this project.

1.1.1 Rolling service doors.

1.1.2 Rolling counter doors.

1.1.3 Rolling grille doors.

1.1.4 Rolling fire doors.

1.1.5 Rolling counter fire doors.

1.1.6 Rolling traffic doors.

1.1.7 Rolling high-speed doors.

1.1.8 Electric operators.

1.2 RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

1.2.1 Section 05 50 00 - Metal Fabrications.

1.2.2 Section 08 71 53 - Security Door Hardware.

1.2.3 Section 09 90 00 - Painting and Coating.

1.2.4 Section 11 12 26.13 - Parking Fee Coin Collection Equipment.

1.2.5 Section 26 05 00 - Common Work Results for Electrical.

1.3 REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

1.3.1 ASTM International (ASTM):

1.3.1.1 ASTM A 240 - Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet and Strips.

1.3.1.2 ASTM A 653/A 653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.

1.3.1.3 ASTM B209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate.

1.3.1.4 ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles and Tubes.

1.4 SUBMITTALS

1.4.1 Submit under provisions of Section 01 30 00 - Administrative Requirements.

1.4.2 Product Data: Manufacturer's data sheets on each product to be used, including:

1.4.2.1 Preparation instructions and recommendations.

1.4.2.2 Storage and handling requirements and recommendations.

1.4.2.3 Installation methods.

1.4.3 Shop Drawings:

1.4.3.1 Provide drawings indicating guide details, head and jamb conditions, spring shafts, anchorage, accessories, finish colors, patterns and textures, operator mounts and other related information.

1.4.3.2 Regulatory Requirements and Approvals: Provide shop drawings in compliance with local Authority Having Jurisdiction (AHJ).

1.4.4 Certifications:

1.4.4.1 Submit manufacturer's certificate that products meet or exceed specified requirements.

1.4.4.2 Submit installer qualifications.

** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.

1.4.5 Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.

1.4.6 Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.

1.5 QUALITY ASSURANCE

1.5.1 Installer Qualifications: Utilize an installer having demonstrated experience on projects of similar size and complexity, and trained and authorized by the door manufacturer to perform the work of this section.

1.6 DELIVERY, STORAGE, AND HANDLING

1.6.1 Store products in manufacturer's unopened packaging until ready for installation.

1.7 PROJECT CONDITIONS

1.7.1 Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.

1.8 WARRANTY

** NOTE TO SPECIFIER ** Warranty for rolling service doors. Delete if not required.

1.8.1 Manufacturer's Warranty for Rolling Service Doors: Provide manufacturer's standard warranty.

1.8.1.1 Raynor warrants the door and its component parts for one (1) year against defects in material and workmanship.

1.8.1.2 Raynor warrants the electrical operator and its component parts for two (2) year against defects in material and workmanship.

** NOTE TO SPECIFIER ** Warranty for rolling counter doors. Delete if not required.

1.8.2 Manufacturer's Warranty for Rolling Counter Doors: Provide manufacturer's standard warranty.

1.8.2.1 Raynor warrants the door and its component parts for one (1) year against defects in material and workmanship.

** NOTE TO SPECIFIER ** The warranty is one year for all tube motors. All other motor operators are two year warranty. Delete warranty not required.

1.8.2.2 Raynor warrants the electrical operator and its component parts for one (1) year against defects in material and workmanship.

1.8.2.3 Raynor warrants the electrical operator and its component parts for two (2) year against defects in material and workmanship.

** NOTE TO SPECIFIER ** Warranty for rolling grille doors. Delete if not required.

1.8.3 Manufacturer's Warranty for Rolling Grille Doors: Provide manufacturer's standard warranty.

1.8.3.1 Raynor warrants the door and its component parts for one (1) year against defects in material and workmanship.

1.8.3.2 Raynor warrants the electrical operator and its component parts for two (2) year against defects in material and workmanship.

** NOTE TO SPECIFIER ** Warranty for rolling fire doors. Delete if not required. Operator models FGH and FSE have a one (1) year warranty. Operator models FDC and FDCL have a two (2) year warranty.

1.8.4 Manufacturer's Warranty for Rolling Fire Doors: Provide manufacturer's standard warranty.

1.8.4.1 Raynor warrants the door and its component parts for one (1) year against defects in material and workmanship.

** NOTE TO SPECIFIER ** The warranty is one year for all tube motors. All other motor operators are two year warranty. Delete warranty not required.

1.8.4.2 Raynor warrants the electrical operator and its component parts for one (1) year against defects in material and workmanship.

1.8.4.3 Raynor warrants the electrical operator and its component parts for two (2) year against defects in material and workmanship.

** NOTE TO SPECIFIER ** Warranty for rolling counter fire doors. Delete if not required.

1.8.5 Manufacturer's Warranty for Rolling Counter Fire Doors: Provide manufacturer's standard warranty.

1.8.5.1 Raynor warrants the door and its component parts for one (1) year against defects in material and workmanship.

** NOTE TO SPECIFIER ** The warranty is one year for all tube motors. All other motor operators are two year warranty. Delete warranty not required.

1.8.5.2 Raynor warrants the electrical operator and its component parts for one (1) year against defects in material and workmanship.

1.8.5.3 Raynor warrants the electrical operator and its component parts for two (2) year against defects in material and workmanship.

** NOTE TO SPECIFIER ** Warranty for rolling traffic doors. Delete if not required.

1.8.6 Manufacturer's Warranty for Rolling Traffic Doors: Provide manufacturer's standard warranty.

1.8.6.1 Raynor warrants the door and its component parts for one (1) year against defects in material and workmanship.

1.8.6.2 Raynor warrants the electrical operator and its component parts for two (2) year against defects in material and workmanship.

** NOTE TO SPECIFIER ** Warranty for rolling high-speed doors. Delete if not required.

1.8.7 Manufacturer's Warranty for Rolling High-Speed Doors: Provide manufacturer's standard warranty.

1.8.7.1 Raynor warrants the motor for five (5) years against defects in material and workmanship.

** NOTE TO SPECIFIER ** Warranty for ControlHoist 2.0 commercial operators, operator only. Delete if not required.

1.8.8 Manufacturer's Warranty for ControlHoist 2.0 Commercial Operators: Provide manufacturer's standard warranty.

1.8.8.1 Raynor warrants the electrical operator and component parts for two (2) years against defects in material and workmanship when purchased as operator only.

** NOTE TO SPECIFIER ** Warranty for ControlHoist 2.0 commercial operators, door and operator. Delete if not required.

1.8.9 Manufacturer's Warranty for ControlHoist 2.0 Commercial Operators Door and Operator Warranty Package: Provide manufacturer's standard warranty.

1.8.9.1 Raynor warrants the electrical operator and component parts against defects in material and workmanship for three (3) years, on the operator only, when purchased with any model of Raynor commercial sectional or rolling door.

2 PRODUCTS

2.1 MANUFACTURERS

2.1.1 Acceptable Manufacturer: Raynor, which is located at: 1101 East River Rd. P. O. Box 448; Dixon, IL 61021-0448; Toll Free Tel: 800-4-RAYNOR; Tel: 815-288-1431; Fax: 888-598-4790; Email:request info (); Web:

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

2.1.2 Substitutions: Not permitted.

2.1.3 Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.

** NOTE TO SPECIFIER ** Delete Rolling Service Doors if not required.

2.2 ROLLING SERVICE DOORS

** NOTE TO SPECIFIER ** DuraCoil is for interior or exterior applications up to 40 ft in width and 30 ft in height with slat restrictions.

2.2.1 DuraCoil as manufactured by Raynor Garage Doors:

2.2.1.1 Doors:

2.2.1.1.1 Operation:

** NOTE TO SPECIFIER ** Delete door operation not required. There are restrictions on size of door for push-up and hand chain operation.

2.2.1.1.1.1 Provide doors designed for push-up operation.

2.2.1.1.1.2 Provide doors designed for hand chain operation.

2.2.1.1.1.3 Provide doors designed for electric motor operation.

2.2.1.1.2 Structural Performance Requirements:

** NOTE TO SPECIFIER ** Insert required wind load. Standard is 20 psf.

2.2.1.1.2.1 Wind Loads: Uniform pressure of: ______psf.

** NOTE TO SPECIFIER ** Delete this section if not relevant to this project. Delete slat type not required.

2.2.1.1.3 International Residential Code (IRC) Wind Load Compliance Requirements:

2.2.1.1.3.1 Flat Slat Style FF DuraCoil Steel Roll-Up Doors, Impact Resistant.

2.2.1.1.3.2 Insulated Flat Slat Style IF DuraCoil Steel Roll-Up Doors, Impact Resistant.

** NOTE TO SPECIFIER ** Delete this section if not relevant to this project. Delete slat type not required.

2.2.1.1.4 International Building Code (IBC) Wind Load Compliance Requirements:

2.2.1.1.4.1 Flat Slat Style FF DuraCoil Steel Roll-Up Doors, Non-Impact Resistant.

2.2.1.1.4.2 Insulated Flat Slat Style IF DuraCoil Steel Roll-Up Doors, Non-Impact Resistant.

** NOTE TO SPECIFIER ** Delete this section if not relevant to this project. The required slat type must be an insulated slat with header weatherseal.

2.2.1.1.5 International Energy Conservation Code (IECC) Requirements:

2.2.1.1.5.1 Air Infiltration - Maximum air leakage of 1.00 cfm/ft2 is required. Testing shall be in accordance with DASMA 105 test procedure.

2.2.1.1.5.2 Raynor provides an air leakage rating of .47 cmf/ft2.

2.2.1.1.5.3 Raynor provides a U-Factor rating of 0.901 Btus/Ft2-HR-OF on DuraCoil Rolling Steel Model IF (Insulated Flat Slat).

** NOTE TO SPECIFIER ** Delete this section if not relevant to this project. The required slat type must be an insulated slat with header weatherseal.

2.2.1.1.6 Sound Transmission Class (STC) Rating:

2.2.1.1.6.1 STC rating of 22 required on an insulated door.

2.2.1.1.6.2 STC rating of 23 required on an insulated door with header weatherseal.

2.2.1.2 Curtain: Interlocking roll-formed slats as specified below. Endlocks shall be attached to each of alternate slat to prevent lateral movement.

** NOTE TO SPECIFIER ** Delete slat styles and gauges not required. Slat type and gauge is depending on size of door. Contact manufacturer for more information. Standard gauge is 22. Refer to the following paragraph for Light-Duty Flat Slat (LFF) Model.

2.2.1.2.1 Flat Slat Style: FF.

2.2.1.2.1.1 Steel: 18 gauge (0.047 inch minimum thickness).

2.2.1.2.1.2 Steel: 20 gauge (0.036 inch minimum thickness).

2.2.1.2.1.3 Steel: 22 gauge (0.030 inch minimum thickness).

2.2.1.2.1.4 Steel: 24 gauge (0.024 inch minimum thickness).

2.2.1.2.1.5 Stainless Steel: 20 gauge (0.033 inch minimum thickness).

2.2.1.2.1.6 Stainless Steel: 22 gauge (0.027 inch minimum thickness).

2.2.1.2.1.7 Aluminum: 16 gauge (0.050 inch minimum thickness).

2.2.1.2.1.8 Aluminum: 18 gauge (0.040 inch minimum thickness).

2.2.1.2.2 Large Contour Slat Style: LC.

2.2.1.2.2.1 Steel: 18 gauge (0.047 inch minimum thickness).

2.2.1.2.2.2 Steel: 20 gauge (0.036 inch minimum thickness).

2.2.1.2.2.3 Steel: 22 gauge (0.030 inch minimum thickness).

2.2.1.2.3 Small Contour Slat Style: SC.

2.2.1.2.3.1 Steel: 20 gauge (0.036 inch minimum thickness).

2.2.1.2.3.2 Steel: 22 gauge (0.030 inch minimum thickness).

2.2.1.2.4 Flat Insulated Slat Style: IF. Polyurethane insulation with R-value 8.0 and U-value 0.125.

2.2.1.2.4.1 Steel: 18 gauge (0.047 inch minimum thickness) with 24 gauge back covers (0.023 inch minimum thickness).

2.2.1.2.4.2 Steel: 20 gauge (0.036 inch minimum thickness) with 24 gauge back covers (0.023 inch minimum thickness).

2.2.1.2.4.3 Steel: 22 gauge (0.030 inch minimum thickness) with 24 gauge back covers (0.023 inch minimum thickness).

2.2.1.2.4.4 Steel: 24 gauge (0.023 inch minimum thickness) with 24 gauge back covers (0.023 inch minimum thickness).

2.2.1.2.4.5 Stainless Steel: 20 gauge (0.033 inch minimum thickness) with 24 gauge back covers (0.023 inch minimum thickness).

2.2.1.2.4.6 Stainless Steel: 22 gauge (0.027 inch minimum thickness) with 24 gauge back covers (0.023 inch minimum thickness).

2.2.1.2.4.7 Aluminum: 16 gauge (0.050 inch minimum thickness) with 18 gauge back covers (0.040 inch minimum thickness).

2.2.1.2.4.8 Aluminum: 18 gauge (0.040 inch minimum thickness) with 18 gauge back covers (0.040 inch minimum thickness).

2.2.1.2.5 Flat Perforated Slat Style: F.

** NOTE TO SPECIFIER ** Delete slat types not required.

2.2.1.2.5.1 Steel: 20 gauge (0.036 inch minimum thickness) punched with 1/16 inch (1.6mm) diameter holes staggered on 3/32 inch (2.4mm) centers across entire length.

2.2.1.2.5.2 Steel: 22 gauge (0.030 inch minimum thickness) punched with 1/16 inch (1.6mm) diameter holes staggered on 3/32 inch (2.4mm) centers across entire length.

2.2.1.2.5.3 Steel: 16 gauge (0.050 inch minimum thickness) punched with 1/16 inch (1.6mm) diameter holes staggered on 3/32 inch (2.4mm) centers across entire length.

2.2.1.2.5.4 Steel: 18 gauge (0.040 inch minimum thickness) punched with 1/16 inch (1.6mm) diameter holes staggered on 3/32 inch (2.4mm) centers across entire length.

** NOTE TO SPECIFIER ** Delete material not required. Note: Stainless steel is not available on Small Curve, Large Curve, and Perforated Flat slats. Aluminum is not available on Small Curve and Large Curve slats.

2.2.1.2.6 Material:

2.2.1.2.6.1 Commercial quality hot-dipped galvanized (G-90) steel in accordance with ASTM A-653.

2.2.1.2.6.2 Stainless steel in accordance with ASTM A-240, type 304.

2.2.1.2.6.3 Aluminum in accordance with ASTM B-209, alloy 5005, temper H34.

2.2.1.2.7 Color and Finish:

** NOTE TO SPECIFIER ** Delete color/finish not required. Small and Large curve slats available with gray and ArmorBrite finishes only. Perforated slats available with gray, clear anodize, and ArmorBrite finishes only.

2.2.1.2.7.1 One finish coat of gray polyester paint applied over one coat of primer.

2.2.1.2.7.2 One finish coat of tan polyester paint applied over one coat of primer.

2.2.1.2.7.3 One finish coat of white polyester paint applied over one coat of primer.

2.2.1.2.7.4 Galvanized finish.

2.2.1.2.7.5 Stainless steel #4 finish.

2.2.1.2.7.6 Clear anodize finish.

2.2.1.2.7.7 Bronze anodize finish.

2.2.1.2.7.8 ArmorBrite powdercoat finish.

** NOTE TO SPECIFIER ** Insert color below.

2.2.1.2.7.8.1 Color: ______.

2.2.1.3 Endlocks: Zinc-plated malleable cast iron endlocks fastened with two zinc-plated steel rivets.

2.2.1.4 Bottom Bar: Two angles, minimum 1-1/2 inches by 1-1/2 inches by 1/8 inch (38.1 mm x 38.1 mm x 3.2 mm) with single-contact type bottom astragal.

2.2.1.4.1 Material:

** NOTE TO SPECIFIER ** Delete material not required. Note: Roll-formed galvanized steel angles available on doors 20' wide or less. Break-formed stainless steel angles available on doors 12' wide or less.

2.2.1.4.1.1 Roll-formed galvanized steel angles.

2.2.1.4.1.2 Structural steel angles.

2.2.1.4.1.3 Structural aluminum angles.

2.2.1.4.1.4 Break-formed stainless steel angles.

2.2.1.4.1.5 Structural stainless steel angles.

** NOTE TO SPECIFIER ** Delete color and finish not required.

2.2.1.4.2 Color and finish:

2.2.1.4.2.1 Structural angle bottom bar to receive one coat of black rust-inhibitive primer.

2.2.1.4.2.2 Roll-formed steel angles to be galvanize finish.

2.2.1.4.2.3 Break-formed stainless steel angles #4 finish.

2.2.1.4.2.4 Structural stainless steel angles mill finish.

2.2.1.4.2.5 Structural aluminum angles to be clear anodize finish.

2.2.1.4.2.6 Structural aluminum angles to be bronze anodize finish.

2.2.1.4.2.7 ArmorBrite Powdercoat finish.

** NOTE TO SPECIFIER ** Insert color below.

2.2.1.4.2.7.1 Color: ______.

** NOTE TO SPECIFIER ** Delete the following paragraph if no vision panels or retain only vision panel types required for the project. Number and locations of vision panels to comply with door elevation drawings.

2.2.1.5 Vision Panels: 4 inches by 1 inch (101.6 mm by 25.4 mm) plexiglass, thickness as follows:

2.2.1.5.1 1/8 inch (3.2 mm) thick for flat slats.

2.2.1.5.2 5/8 inch (15.9 mm) thick for insulated slats.

2.2.1.6 Guide Assemblies: Three structural angles, minimum 3 inches by 2 inches by 3/16 inch (76 mm by 50.8 mm by 4.8 mm) and fitted with removable curtain stops.

2.2.1.6.1 Material and Finish:

** NOTE TO SPECIFIER ** Delete material and finish not required. Standard is primer.

2.2.1.6.1.1 Structural steel to receive one coat of black rust-inhibitive primer.

2.2.1.6.1.2 Structural steel to receive one coat of hot-dipped galvanized.

2.2.1.6.1.3 Structural stainless steel with a mill finish.

2.2.1.6.1.4 Structural steel to receive ArmorBrite Powdercoat finish.

** NOTE TO SPECIFIER ** Insert color below.

2.2.1.6.1.4.1 Color: ______.

** NOTE TO SPECIFIER ** Delete guide weatherseal if not required.

2.2.1.7 Guide Weatherseal: Seals to inhibit air infiltration between the guide and the curtain.

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs. Brushseal recommended for small and large curve slats.

2.2.1.7.1 Snap-on dual durometer vinyl seal.

2.2.1.7.2 Brushseal with an aluminum retainer.

2.2.1.8 Counterbalance:

2.2.1.8.1 Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 m) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.