ClassicLXRSRS230-260
User'sInstructions
WallMounted,BalancedFlueGasBoilers
NaturalGasModels
DeluxemodelsG.C.ApplianceNo.
ClassicLXRS230...... 41 387 33
ClassicLXRS240...... 41 387 34
ClassicLXRS250...... 41 387 35
ClassicLXRS260...... 41 387 36
StandardmodelsG.C.ApplianceNo.
ClassicRS230...... 41 387 10
ClassicRS240...... 41 387 11
ClassicRS250...... 41 387 12
ClassicRS260...... 41 387 13
DeluxemodelStandardmodel
CAUTION.Toavoidthepossibilityofinjuryduringtheinstallation,servicingorcleaningofthisappliance,careshouldbetakenwhenhandlingedgesofsheetsteel
GASSAFETY(INSTALLATIONANDUSE)Regulations,
1994,amendments1996orrulesinforce.
ItislawthatallgasappliancesareinstalledbyaCORGIregistered
installer(identifiedby )inaccordancewiththe aboveregulations.Failuretoinstallappliancescorrectlycouldleadtoprosecution.Itisinyourowninterest,andthatofsafety,toensurethelawiscompliedwith.
Itisessentialthattheinstructionsinthisbooklet are strictlyfollowedforsafeandeconomical operation of the boiler.
ELECTRICITYSUPPLY
Thisappliancemustbeefficientlyearthed.Thisappliancerequires230V~50Hz.
Thisappliancemustbeconnectedtothesupplyviaadoublepoleswitch,fusedat3A,havinga3mm(1/8")contactseparationinbothpoles,servingonlytheboilerandsystemcontrols.
MINIMUMCLEARANCES
TheminimumclearancesgivenbelowMUSTbecompliedwithinordertomaintainthesaferunningoftheboilerandtofacilitateservicing.
Above the boiler100mm (4")
Ateachsideoftheboiler5mm (1/4")
Underneaththeboiler100mm (4")
Infrontoftheboiler450mm (173/4")
IMPORTANTNOTES
a. Thisappliancemustnotbeoperated withoutthe casingcorrectlyfittedandforminganadequateseal.
b. Iftheboilerisinstalledinacompartmentthenthecompartment
MUSTNOTbeusedforstoragepurposes.
c. TheventilationprovidedfortheboilerduringinstallationMUST NOTbeblockedandacheckshouldbe made periodicallythattheventilationareasarefreefromanyobstruction.
d. Ifitisknownorsuspectedthatafaultexistsontheboilerthenit MUST NOT be used until the fault has been corrected bya CORGIregisteredinstaller.
TOLIGHTTHEBOILER. Referto Frame 1
1. CHECK THATTHEELECTRICITYSUPPLYTOTHEBOILERISOFF.
2. Deluxe Model(LX)
Lifttheglassfasciaandsupportwithslidingcatch.
Standardmodel.
Openthecontrolsaccessdoorbyhingingdownwards.
3. Ensure that the gas inlet cock (E) isOPEN.
4. Ensurethattheboilerthermostatknob(C)isintheOFF(0)
position.
5. Turnthegascontrolknob(A)totheRIGHTuntilresistanceisfelt,thenreleaseit. WAITFOR3MINUTES
6. Pushinthegascontrolknob(A)andholditdepressed.Pushinandreleasetheigniterbutton(D)repeatedlyuntilthepilotflamecanbeseenthroughthesightglass(B).Whenthepilothaslit,continuetopressinthegascontrolknobforafurther
15seconds.
7. Shouldthepilotgooutatthisoranyotherstageturnthegascontrolknob(A)totheRIGHT.
WAITFOR3MINUTESthenrepeatinstruction6butwaitforlongerthan15secondsbeforereleasingthegascontrolknob(A).
8. Switch ONthe electricity supply to the boiler. Checkthatallexternalcontrols,e.g.roomthermostatetc.,areON.
9. Turntheboilerthermostatknob(C)toposition6andtheboilerwilllight.Settheboilerthermostattothedesiredposition.
10.DeluxeModel(LX)
Lowertheglassfasciaafterpushingintheslidingcatch.
Standardmodel.
Closethecontrolsaccessdoor.
Inwinterconditions,i.e.centralheatinganddomestichotwater, thethermostatshouldbesetatposition5or6.
Forsummerconditions,i.e.domestichotwater only, thethermostatshouldbesetatposition3.
Thesesettings,however,areofferedforgeneralguidanceonlyandothersettingsmaybefoundpreferable,dependentuponthetypeofsysteminstalledorasrecommendedbytheinstaller.
Approx. flow temperatures for the boiler thermostat settings are:
KnobSettingFlowTemperature
THELOGBOOKSHOULDBECOMPLETEDAFTER EACHSERVICEANDKEPTWITHTHESE INSTRUCTIONS
2ClassicLXRS & RS-User's
1BOILERCONTROLS
StandardModelDeluxeModel
LEGEND
A. Gascontrolknob
B. Sightglass
C. Thermostatknob
D. Igniterbutton
E. Gasinletcock(shownintheOPEN
position)
F. Overheatthermostatresetbutton(iffitted)
Viewinsidecontrolsarea
TOSHUTDOWNTHEBOILER
1. For shortperiods
TurntheboilerthermostatknobtoOFF. Whenheatingisagainrequired,restoretheknobtoitsoriginalsettings.
2. For longerperiods
TurntheboilerthermostatknobtoOFF. Turnthegascontrolknob(A)totherightuntilresistanceisfeltthenreleaseittoextinguishthepilotburner.
Switch the electricity supply toOFF.
WARNING. If no frost protection is provided and frost islikelyduringa short absence from home, leave the heating controls at areducedtemperaturesetting.
Forlongerperiods,theentiresystemshouldbedrained-includingthedomesticwatersupply. Ifthesystem includesafrostthermostatthen,duringcoldweather,theboilershouldbeturnedOFFatthetimeswitch(es)ONLY.ThemainssupplyshouldbeleftswitchedON, withtheboilerthermostatleftinthenormalrunningposition.
ClassicLXRS RS-User's
BOILEROVERHEATTHERMOSTAT(Iffitted)
Theboilerisfittedwithasafety'cutout'thermostat.Thisthermostatwillextinguishthepilotandshutdowntheboilerintheeventofoverheating.
Should this occur allow the boiler to cool, press the resetbutton
(F) then relight as detailed in steps 1-10 in 'To light theboiler'.
IfthecutoutconditionstillpersiststhenturnofftheboilerandconsultaCORGIregisteredinstaller.
CONTROLOFWATERTEMPERATURE
1. Adjusttheboilerthermostat(C)togivetherequiredtemperatureforcentralheating.
2. TheboilerthermostatautomaticallyswitchesthemainburnerOFFandONtomaintaintheselectedtemperature.Thepilotburnerremainsalightcontinuouslytogivere-ignitionofthemainburner.
3
TORELIGHTTHEBOILER
Repeattheprocedurefrom1-10,detailedin'Tolighttheboiler'.
LOSSOFSYSTEMWATERPRESSURE
StandardboilersfittedwithClassicSealedSystemUnitsonly
Iftheredarrowonthemodulepressuregaugeissetabovezeroandthesystempressureisseentofallbelowthisvalueoveraperiodoftimethenawaterleakisindicated. InthiseventaCORGIregisteredinstallershouldbeconsulted.
DONOTOPERATETHEBOILERIFTHEPRESSUREHASREDUCEDTOZEROFROMTHEORIGINALSETTING.
ESCAPEOFGAS
Shouldagasleakbesuspected,contactyourgassupplierwithoutdelay.
DoNOTsearchforgasleakswithanakedflame.
CLEANING
Fornormalcleaningsimplydustwithadrycloth.
Toremovestubbornmarksandstains,wipewithadampclothandfinishoffwithadrycloth.
DoNOTuseabrasivecleaningmaterials.
MAINTENANCE
Theapplianceshouldbeservicedatleastonceayearbya
CORGIregisteredinstaller.
Caradon Plumbing Limited, P.O.Box 103, National Ave,Kingston upon Hull, HU5 4JN.Telephone: 01482492251Fax:01482448858.RegistrationNo.London322137.RegisteredOffice:National Avenue, Kingston upon Hull, HU5 4JN.Asubsidiary of Caradon plc
CERTIFIEDPRODUCT
ManufacturedunderaBSENISO9001:1994
QualitySystemacceptedbyBSI
THIS SYMBOL IS YOUR ASSURANCEOFQUALITY
Theseappliancesaredesignedforusewith NaturalGasonly.Theyhavebeentestedand conformwiththeprovisionsofBS.6332andBS.
5258.
Thecodeofpracticefortheinstallation, commissioningservicingofcentralheatingsystems
CaradonPlumbingLimitedisamemberofthe
Benchmarkinitiativeandfullysupportstheaimsofthe
LXFF.87/AQ/220
LXRS.87/AQ/221
FF.87/AP/107
RS.87/AP/108
NaturalGas appliancesare servicelistedbyBritishGas
programme. Benchmarkhasbeenintroducedto improvethestandardsofinstallationand commissioningofcentralheatingsystemsintheUKandtoencouragetheregularservicingofallcentralheatingsystemstoensuresafetyandefficiency.
CaradonPlumbingLimited pursuesapolicyof continuingimprovement in the design and performance of its products. Therightisthereforereservedtovaryspecificationwithoutnotice.
September1999UIN111500A04
Ideal Consumer Helpline Tel:01482498660