CEN prEN STANDARDS: Last updated (9th March 2005)

Note: These are the English version of the standards that have been submitted to CEN-CMC to prepare for public inquiry. The substance will not change, but there may be some minor editing. The public inquiry drafts of these standards will be published in April 2005.

Key: Yellow – on CIRCA; Blue: WG Drafts (not prEN drafts), some on CIRCA; White – not received

Pren
N° / WI / Work item / Present Stage / Responsible
TC / Contact Details / Comments /
UMBRELLA DOCUMENT: An outline of the calculation procedure for assessing the energy performance of buildings. / Draft 2.0 / CEN/BT/WG 173[1] / Brian Anderson (UK) / Will not be published for public inquiry. Next version will be available in March/April.
Comments to:
Overview of relations between EPBD standards and appendix: Detailed relations between CEN standards for the EPBD (demo version) / Draft 1.0 / CEN/BT/WG 173 / Dick Van Dijk (NL) / Issued 15th July.
2 .pdf files.
Comments to:

Section 1. Standards concerned with overall energy use in buildings (based on results from standards in section 2)
1 + 3. / Energy performance of buildings – Methods for expressing energy performance and for energy certification of buildings / prEN
+
---- / TC 89[2]
WG4 / Contact: Jean-Christophe Visier (FR)
Experts: Dick van Dijk (NL); Marleen Spiekman; Claude-Alain Roulet (CH) / prEN draft issued 31st January 2005.
Contact:
2. / Energy performance of buildings – Overall energy use, primary energy and CO2 emissions / 32 / TC 228
WG4 / Contact: Johan Zirngibl (FR)
Experts: Erhorn…………….. / WG draft issued 5th March. Waiting for prEN draft.
Comments to:
4. / Energy performance of buildings – Assessment of energy use and definition ratings / 32 / TC 89
WG4 / Contact: Claude-Alain Roulet (CZ)
Experts: Dick Van Dijk (NL), Jean-Christophe Visier (FR) / prEN draft issued 31st January 2005.
Comments to:

5. / Heating systems in buildings – Inspection of boilers and heating systems.[3] / 32 / TC 228[4]
WG2 / Contact: Laurent Socal (IT)
Experts: Hans van Wolferen; J Schilling, B. Young, M. Searle, E.Friedl (AT)
. / WG draft issued 5th March. Waiting for prEN draft.
Comments to: and
6 / Ventilation for buildings – Energy Performance of buildings - Guidelines for the inspection of air-conditioning systems.[5] / 32 / TC 156[6]/WG10 / Contact: Jorma Railio (FI)
Experts: Hitchin (UK); Bernard; Mondot; Millet; Hough; / prEN draft issued 31st January 2005.
Comments to:
Section 2: Standards concerned with calculation of delivered energy (based where relevant on results from standards in section 3)
7. / Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies – Part 1: General / 46
prEN / TC 228
WG4 / Contact: Johan Zirngibl (FR)
Experts: Socal (IT); Erhorn (DE) / prEN 14335.
WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
8. / Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies – Part 2.1: Space heating emission systems / 40 / TC 228
WG4 / Contact: Bjarne Olesen (DK)
Experts: Richter; Visier (FR) / Issued 5th April. Comments by 30th April.
CEN issued response to MS Comments on 5th July.
Comments to:
9. / Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies – Part 2.2: Space heating generation systems: / 31 / TC 228[7]
WG4 / Contact: Johan Zirngibl (FR)
Experts: / Not yet received.
9 / Part 2.2.1. Heat Generation – Combustion systems / 31 / Contact: Johan Zirngibl (FR)
Experts: / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
Comments to:
9 / Part 2.2.2. Heat Generation - Heat pump systems / 11 / TC312 / Contact: Johan Zirngibl (FR)
Experts: / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
Comments to:
9 / Part 2.2.3. Thermal Solar systems / 32 / Contact: Johann Zirngibl (FR)
Experts: JE Nielsen (DK), H Visser (NL) / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
Comments to: and
9 / Part 2.2.4 The performance and quality of CHP electricity and heat (incl on-site and micro-CHP).[8] / 32 / TC132 / Contact: Johann Zirngibl (FR)
Experts: MV Gastel, P. Loffler / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
Comments to:
9 / Part 2.2.5. The performance of quality district heating and large volume systems.[9] / 11 / TC132 / Contact: P Loose (DE)
Experts: J. Zirngibl (FR) / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
Comments to: and
Part 2.2.6. The performance of other renewables heat and electricity.[10] / 32 / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
Comments to:
9 / Part. 2.2.7: Space Heating Generation – Biomass Combustion systems / Experts: E.Friedl (AT), J. Zirngibl (FR), J.Schilling / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
Comments to: and
10 / Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies – Part2.3: Space heating distribution systems / 31 / TC 228 / Task Leader: R. Hirschberg (DE)
Experts: van Wolferen, Socal (IT) / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
Comments to: and
11 / Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies – Part 3.1: Domestic hot water systems,
including generation efficiency and the tap water requirements. / 31 / TC 228
WG4 / Contact: Johan Zirngibl (FR)
Task Leader: M. Searle (UK)
Experts:Soma, Friedl (AT), van Wolferen, Young; Schilling / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
CEN issued response to MS Comments on 5th July.
Comments to: and
11 / Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies – Part 3.2: / 31 / TC 228
WG4 / Contact: Johan Zirngibl (FR)
Task Leader: M. Searle (UK)
Experts:Soma, Friedl (AT), van Wolferen, Young; Schilling / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
Comments to: and
11 / Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies – Part 3.3: / 31 / TC 228
WG4 / Contact: Johan Zirngibl (FR)
Task Leader: M. Searle (UK)
Experts:Soma, Friedl (AT), van Wolferen, Young; Schilling / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
Comments to: and
12 / Ventilation for buildings - Calculation of room temperatures and of load and energy for buildings with room conditioning systems / 31 / TC 156
WG7 / Contact: Gerhard Zweifel (CH)
Experts: Maassen, Millet, Hitchin, v.Wolferen, Orshoven; / prEN draft issued 31st January 2005.
Comments to:

13 / Energy performance of buildings – Energy requirements for lighting. Part 01: lighting energy estimation / 33 / TC 169
WG9 / Contact: Lou Bedocs
Experts: Husanndee; Gasser / prEN draft issued 31st January 2005.
Comments to:
14 / Thermal performance of buildings – Calculation of energy use for space heating and cooling
(Monthly method to calculate cooling demand for EP regulations) / 32 / TC 89
WG4 / Contact: C.A. Roulet (CH)
Experts: v. Dijk (NL), Visier (FR); Millet…… / prEN draft issued 31st January 2005.
Comments to:
(secretariat) and and
15 / Thermal performance of buildings – Calculation of energy use for space heating – Simplified method with extension of scope of EN ISO 13790 / EN ISO
13790 / TC89
WG4 / Contact: C.A. Roulet (CH)
Experts: : v. Dijk (NL), Visier (FR),……
.+CEN/TC89/WG4.. / EN ISO 13790 now published. No more activity. Not on CIRCA.
Section 3: Standards concerned with calculation of net energy for heating and cooling
16 / Thermal performance of buildings – Sensible room cooling load calculation – General criteria and validation procedures / 32 / TC 89
WG6 / Contact: Thomas Frank (CH)
Experts: Millet, Romagnoni, Parand, Krijger, Plokker; / prEN draft issued 16th March.
Contact:


17 / Thermal performance of buildings – Calculation of energy use for space heating and cooling – General criteria and validation procedures / 32 / TC 89
WG6 / Contact: Thomas Frank (CH)
Experts: Millet, Romagnoni, Parand, Krijger, Plokker; Maldonado (PT) / prEN draft issued 16th March.
Contact:

18 / Ventilation for buildings – Calculation methods for the determination of air flow rates in dwellings including infiltration[11] / 64
EN
13465 / TC 156
WG2 / WI 19 will replace this existing standard (EN 13465)
Draft 3/11/04
19 / Ventilation for buildings – Calculation methods for the determination of air flow rates in buildings including infiltration.[12]. / 32 / TC 156
WG7 / Contact: Jean-Robert Millet (FR)
Experts:de Gids; Jardinier; Railio (FI) / prEN draft issued 31st January 2005.
Comments to:
20 + 21 / Ventilation for buildings – Calculation methods for energy losses due to ventilation and infiltration in commercial buildings / 32 / TC 156
WG7 / Contact: Jean-Robert Millet (FR)
Experts:, Jorma Railio (FI); Kurnitski; Jokisalo; Zweifel / prEN draft issued 31st January 2005.
Comments to: and

22 / Calculation methods for energy efficiency improvements by the application of integrated building automation systems[13]. / 31 / TC247/WG6/TG6 / Contact: Manfred Schumacher (CH)
Experts: R. Hirschberg, J. Tödtli, J-Ch. Visier (FR)
Convenor: Dan Napar / prEN draft issued 31st January 2005.
Comments to:
23 / Thermal performance of building components – Dynamic thermal characteristics – Calculation Methods –
Part 1 / Review / TC 89
ISO/TC163/SC2/WG9 / Contact: Brian Anderson (UK) / prEN draft issued 31st January 2005.
Comments to:
23 / Thermal performance of building components – Transmission and ventilation heat transfer coefficients – Calculation Methods
Part 2 / Review / TC 89
ISO/TC163/SC2/WG9 / Contact: Brian Anderson (UK) / prEN draft issued 31st January 2005.
Comments to:
24 / Part 1 Building materials and products - Hygrothermal properties- tabulated design values and procedures for determining declared and design values / Review / TC 89 ISO/TC163/SC2/WG9 / Contact: Brian Anderson (UK) / prEN draft issued 31st January 2005.
Revised EN ISO Standards/ EN ISO 10456, 13370, 14683
Not a new version
Comments to:
24 / Part 2 – Thermal Performance of buildings - Heat transfer via the ground / Review / TC 89 ISO/TC163/SC2/WG9 / Contact: Brian Anderson (UK) / prEN draft issued 31st January 2005.
Revised EN ISO Standards/ EN ISO 10456, 13370, 14683
Not a new version
Comments to:
24 / Part 3 Thermal bridges in building construction – Heat flow and surfaces temperatures – detailed calculations / Review / TC 89 ISO/TC163/SC2/WG9 / Contact: Brian Anderson (UK) / prEN draft issued 31st January 2005.
Revised EN ISO Standards/ EN ISO 10456, 13370, 14683
Not a new version
Comments to:
24 / Part 4 – Thermal bridges in building construction - Linear thermal transmittance – simplified methods and default values / Review / TC 89 ISO/TC163/SC2/WG9 / Contact: Brian Anderson (UK) / prEN draft issued 31st January 2005.
Revised EN ISO Standards/ EN ISO 10456, 13370, 14683
Not a new version
Comments to:
24 / Part 5 – Building components and building elements – thermal resistance and thermal transmittance – calculation method / Review / TC 89 ISO/TC163/SC2/WG9 / Contact: Brian Anderson (UK) / prEN draft issued 31st January 2005.
Revised EN ISO Standards/ EN ISO 10456, 13370, 14683
Not a new version
Comments to:
25 / Ventilation for non residential buildings – Performance requirements for ventilation and room conditioning systems. / Review / TC 156
WG7 / Contact: Jorma Railio (FI) / prEN draft issued 5th March.
26 / Design of Embedded water based surface heating and cooling systems, to facilitate renewable low temperature heating and high temperature cooling. Part 1: Determination of the design heating and cooling capacity / 32 / TC228
WG5 / Contact: Bjarne Olesen (DK)
Experts:Koschenz; de Carli / Issued 5th April. Comments by 30th April.
Comments to:
26 / Part 2: Design, Dimensioning and Installation / TC228
WG5 / Contact: Bjarne Olesen (DK)
Experts:Koschenz; de Carli………….. / Issued 5th April. Comments by 30th April.
Comments to:
DID NOT EXPECT THE STANDARD TO BE IN 3 PARTS
26 / Part 3: Dynamic considerations / TC228
WG5 / Contact: Bjarne Olesen (DK)
Experts:Michele de Carli (IT), Markus Koschenz (CH) / 1st draft issued 5th April. 2nd draft 5th July. 3rd draft 3/11/04
Comments to:
27 / Performance requirements for temperature calculation procedure without mechanical cooling (Detailed) / 51 prEN 13791 / TC89
WG6 / Contact: Thomas Frank
Experts: Millet, Romagnoni, Parand, Krijger, Plokker / prEN 13791. Not on CIRCA
28 / Performance requirements for temperature calculation procedure without mechanical cooling (Simplified) / 53 prEN 13792 / TC89
WG6 / Contact: Thomas Frank
Experts: Millet, Romagnoni, Parand, Krijger, Plokker / prEN 13792. Not on CIRCA.
29 / Economic evaluation procedures related to energy systems in buildings, including renewable energy sources. / 32 / TC228
WG4 / Contact:Bruno Ziegler
Experts:B. Young, C. Francois, L.Breidenbach, B.Reinhard,
Convenor: Johann Zirngibl (FR( / WG Draft (Dec 04) not on CIRCA but can be requested from the Commission.
Comments to: and
NOT IN MANDATE: Economic performance of heating systems in buildings / TC228 WG4 / Convenor: Johann Zirngibl (FR) / CHECK WITH CEN IF THIS IS A NEW WORK ITEM TO SUPPORT WI 29? Issued 5th April.
NEED E-MAIL CONTACT
30 / Ventilation for buildings – Energy performance buildings - Guidelines for inspection of ventilation systems / 32 / TC156
WG7 / Experts: Pierre-Jean Vialle (FR), Anne-marie Bernard (FR), Wanda Rydholm (SW), Claus Haendel (DE), Jean-Robert Millet (FR); Marc Jardinier (FR); Peter Opt’Veld (NL) / prEN draft issued.
Comments to:
31 / Criteria for the Indoor Environment including thermal, indoor air quality, light and noise / 32 / TC156
WG7 / Contact: Bjarne Olesen (DK)
Experts: Olli Seppanen (Fi); Atze Boerstra (NL), Anne Marie Bernard (FR) / prEN draft issued 5th March.
Comments to

7