CabrilloCollege EMT Training Program
Oropharyngeal Airway
Takes or verbalizes body substance isolation precautions
Procedure
/ Yes /No
/Comments
Measure Airway· Size airway from earlobe to corner of patient’s mouth or angle of jaw to midline of the lip.
Insert
· Open patient’s mouth.· Insert the airway with tip toward roof of mouth until it reaches the base of the tongue.
· Gently rotate airway 180 degrees.
· Flange should rest against the outside of the lips.
Reassess Airway/Ventilations
Objective: The examinee will demonstrate proficiency in sizing and placing an oropharyngeal airway.
Equipment: Adult airway manikin, a variety of OPA sizes.
Indications: Unconscious patient with no gag reflex.
Student’s Name______Pass____Fail____
Examiner’s Name______Date______