SECTION 10 14 00

INTERIOR SIGNAGE

DISPLAY HIDDEN NOTES for specifier by using “Tools”/”Options”/“View”/”Hidden Text” or

“More Commands”/”Display”/”Hidden Text”

** NOTE TO SPECIFIER **

.

This section is based on the Elevate Sign System of APCO Graphics, Inc., which is located at:

388 Grant St. S.E.

Atlanta, GA 30312

Toll Free Tel: (877) 988-2726

Local: (404) 688-9000

Fax: (404) 577-3847

Email:

Web:

PART 1 GENERAL

1.1SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

A.A modular, frameless sign system with options for identification, informational, personnel, directory, directional and regulatory signage.

1.2RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

A.Section 10 11 00–Visual Display Surfaces.

B.Section 10 13 00 - Directories.

C.Section 10 14 26 – Post and Panel / Pylon Signage.

D.Section 10 14 33 – Illuminated Panel Signage.

E.Section 10 14 36 - Non-Illuminated Panel Signage.

1.3REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

A.ANSI A117.1: Providing Accessibility and Usability for Physically Handicap People, 1986 edition.

B.Department of Justice, Office of the Attorney General, "Americans with Disabilities Act", Public Law 101-336, (ADA).

C.2010 Standards for Accessible Design (SAD): The updated ADAAG (ADA Accessibility Guidelines), effective on March 15, 2011 and made mandatory on March 16, 2012.

1.4GENERAL INFORMATION

A.Signage under this section is intended to include items for identification, direction, control, and information within a building where installed as a complete integrated system from a single manufacturer.

B.ADA Design Requirements:

1.Provide signage that conforms to the requirements of all regulatory agencies holding jurisdiction.

2.Comply with all applicable provisions of the 2010 Standards for Accessible Design (the updated ADA Accessibility Guidelines, ADAAG - effective in March 2011. Requirements include, but are not limited to the following:

a.Tactile copy must be all upper case and raised at least 1/32”. Tactile characters must be sans serif, not italic, not oblique, script or highly decorative.

b.The stroke width of the upper case “I” has to be 15% of the letter height or less. The character width of the uppercase “O” must be between 55% and 100% of the height of the corresponding uppercase “I”.

c.The copy height for tactile information must be between 5/8” and 2”. If separate visual characters are provided, raised characters can be ½” and need not contrast with the background.

d.The distance between characters on tactile copy must be a minimum of 1/8” and a maximum of 4 times the character stroke width. These distances are measured between the closest points of adjacent characters.

e.Spacing between lines of tactile copy needs to be a minimum of 135% and a maximum of 170% of the corresponding upper case “I” height (measured from baseline to baseline).

f.Braille must be Grade II and positioned directly below the corresponding raised characters. If text is multi-lined, Braille is placed below the entire body of text and separated 3/8” from any other tactile characters and 3/8” minimum from raised borders and decorative elements.

g.Visual characters and symbols, and their background, are to have a non-glare finish. The color of raised characters must contrast as much as possible with their background to make sure signs are more legible for persons with low vision.

h.Pictograms, selected from International Standards, are to be located within a 6” vertical void and accompanying text descriptions are to be located directly below the pictogram.

1.5SUBMITTALS

A.Submit under provisions of Section 01300.

B.Product Data:

Manufacturer's data sheets on each product to be used, including:

1.Manufacturer's product literature indicating units and designs selected.

2.Evidence of manufacturer's computerized data retrieval program for tracking of project for sign typography, message strip requirements and other pertinent data from schedule input to final computerized typography on finished product.

3.Preparation instructions and recommendations.

4.Storage and handling requirements and recommendations.

5.Installation methods.

C.Samples: One full size sign sample illustrating the design, construction, colors, typestyles, mounting method and other details as specified. Provide sample in small size sign.

NOTE TO SPECIFIER ** Delete provision not required.

1.Samples will be returned for use in Project.

2.Samples will not be returned for use in Project.

D.Shop Drawings:

1.Indicate materials, sizes, configurations, and applicable mountings.

2.Typography sample for typical inserts.

NOTE TO SPECIFIER ** Option. Delete if not required.

3.Artwork for special graphics.

NOTE TO SPECIFIER ** Option. Delete if not required.

4.Artwork for special headers.

E.Signage Schedule:

Complete with location of each sign and the required copy/text.

F.Sign Program Maintenance Plan:

1.Manufacturer shall provide details of software and system of pre-perforated paper sign inserts allowing client to update and maintain signage graphics in-house.

2.Manufacturer shall provide details of an Online Reordering & Maintenance Application whereby the client can submit sign reorders online and store relevant project information such as sign type drawings, message schedules and product instructions.

G.Contract close out:

1.Furnish appropriate checklist for aiding in reordering after Date of Substantial Completion. Maintain computer schedule program for five years for ordering new signage required by Owner.

2.Maintenance data and cleaning requirements for sign surfaces.

NOTE TO SPECIFIER ** Manufacturer has available software program for personal computers - pc, called "SignWord Pro" enabling end user to produce graphics on insert or sign face. Information in main catalog, Call manufacturer directly at listed telephone number for more info. Delete if not required.

3.Furnish one complete SignWord Pro software package compatible with Windows XP or newer.

NOTE TO SPECIFIER ** Option. Delete if not required.

1.6QUALITY ASSURANCE

A.Manufacturer Qualifications:

1.Work required under this section from manufacturer regularly engaged in work of this type and scope for a minimum of 5 years.

2.Maintain computer link between schedule input and computerized typography production.

B.Installer Qualifications: Trained and authorized by manufacturer for installations of required scope and product.

** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.

C.Mock-Up:

Provide a mock-up for evaluation of surface preparation techniques and application workmanship.

1.Finish areas designated by Architect.

2.Do not proceed with remaining work until workmanship, graphics, and installation are approved by Architect.

3.Refinish mock-up as required to produce acceptable work.

1.7DELIVERY, STORAGE & HANDLING

A.Package signs to prevent damage during shipment, handling, storage and installation. Products are to remain in their original packaging (unless otherwise specified) until removal is necessary for installation.

B.If installation site is not ready for signage upon delivery, store signs in a dry, air-conditioned environment.

C.Handle signage in accordance with manufacturer’s instructions.

D.Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.

1.8PROJECT CONDITIONS

A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

1.9SEQUENCING AND SCHEDULING

A.Schedule system installation after room finishes and fixtures have been completed.

1.10WARRANTY

A.Product Warranty: Provide manufacturer’s warranty against defects in materials and workmanship for a minimum period of one year.

PART 2 PRODUCTS

2.1ACCEPTABLE MANUFACTURERS

A.Signage shall be manufactured by APCO Graphics, Inc. (a.k.a. APCO Signs or APCO USA), at 388 Grant Street SE, Atlanta, GA 30312.

2.2ACCEPTABLE PRODUCT

A.ElevateFrameless Modular Sign System

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

B.Substitutions not permitted.

C.Requests for substitutions will be considered in accordance with provisions of Section 01600.

2.3SYSTEM REQUIREMENTS

A.General:

1.Sign system shall be frameless and shall feature solutions for all required sign types, including but not limited to wall mounted personnel signs, work station personnel signs, primary room identification, directories, directionals, overhead signs, projection wall signs, restroom signs, regulatory and information signs, stair signs and changeable slide conference room signs. All signs within the system must convey a uniform look throughout.

B.Features:

1.Sign Assembly:

Sign shall feature a fully recessed chassis to which modular display panels securely engage, creating a frameless look with the appearance that display panels are floating off of the mounting surface.

2. Display Panels / Inserts:

Primary display panels shall be 1/8”thick painted acrylic plaques or 1/8” thick satin anodized aluminum plaques with direct-print graphics.Optional display panels shall be 3mm(1/8”) aluminum composite plaques with the .012” aluminum skin formed precisely around all four edges of the panel to conceal the panel’s composite core. Display panels engage with the concealed chassis in a precise manner to ensure a 1/16” reveal between all panels as a standard. An optional No-Reveal solution enables all panels to butt directly against one another with no inter-insert reveals.

3.Full Bleed Graphics:

System shall offer options for direct-print graphics that bleed around all four edges/returns of the display panels.

4.Tamper Resistance:

System must offer an option for a concealed locking method to increase level of tamper resistance.

5.Mounting:

Signs must be able to accommodate installation via fully concealed mechanical fasteners.

6.Modularity:

All display panels shall be securely engaged within a concealed chassis but must be easily updatable to accommodate change. Display panels must be removable without the use of a special, proprietary tool.

7.User Letter Paper Inserts:

System must offer solutions for user updatable paper inserts, including a range of perforated, coated paper and free software with templates for easy creation of graphics.

C.Graphics and Typography:

As selected from manufacturer’s standards. Reference sign drawings.

D.Colors and Finishes:

As selected from manufacturer’s standards. Reference sign drawings.

E.ADA Compliance:

Sign system shall comply with all applicable provisions of the 2010 Standards for Accessible Design (the updated ADA Accessibility Guidelines, ADAAG), effective in March 2011. This includes requirements regarding which sign types require Braille/tactile features, character heights, raised character spacing, raised character stroke width, color contrast and installation locations and mounting heights within the facility.

F.Materials and Construction:

1.Sign shall feature a fully recessed black anodized aluminum chassis to which modular display panels securely engage. Chassis shall be no more than 3/8" in depth and shall be recessed sufficiently behind the panels to give the appearance the panels/inserts are floating off of the mounting surface.

2.Primary display panels shall be 1/8” thick painted acrylic or 1/8” satin anodized aluminum with direct-print graphics. Optional display panels for full-bleed graphics shall be 3mm (1/8”) thick aluminum composite (ACM) with the .012” aluminum face formed precisely around all four edges of the panel to conceal its composite core. Display panels must securely engage with the recessed chassis via a concealed attachment method but should be 100% modular to accommodate changes.

3.System shall offer a range of aluminum bands to house user-updatable, perforated paper inserts. Inserts shall be retained on the left and right sides of the aluminum band by .020” clear, flexible end caps.

4.Standard ADA inserts/plaques are acrylic or aluminum with APCO’s DP-Tactile processdirect-print, UV-cured 1/32” thick tactile characters and fully domed Braille.

5. Standard graphics are UV-cured, direct-print with true 600dpi resolution and the option to bleed around all four edges/returns of the ACM display panels.

6.Attachment: Signs shall be able to accommodate fully concealed mechanical

fasteners.

2.4Elevate Sign System Components

Reference drawings for colors, finishes, sizes and details. Reference signage schedule

for graphics/copy specifications.

NOTE TO SPECIFIER ** Delete options if not required.

A.Sizes and Configurations:

NOTE TO SPECIFIER ** Delete options from 1, 2 and 3 following if not required.

1.Custom configurationswith the following widths and variable heights. Insert/display components are specified in Section D following.

a.6” (EV06)

b.8.5” (EV85)

c.11” (EV11)

d.14” (EV14)

e.17” (EV17)

f.22” (EV22)

2.Configurations selected from manufacturer’s Corporate, Education or Healthcare Solutions catalogs.

NOTE TO SPECIFIER ** Delete options if not required.

a.Elevate Corporate Solutions

i.Series 1: EVC1-____(specify product codes that apply)

ii.Series 2: EVC2-____(specify product codes that apply)

iii.Series 3: EVC3-____ (specify product codes that apply)

b.Elevate Education Solutions

i.Series 1: EVE1-____ (specify product codes that apply)

ii.Series 2: EVE2-____ (specify product codes that apply)

iii.Series 3: EVE3-____ (specify product codes that apply)

c.Elevate Healthcare Solutions

i.Series 1: EVH1-____ (specify product codes that apply)

ii.Series 2: EVH2-____ (specify product codes that apply)

iii.Series 3: EVH3-____ (specify product codes that apply)

3.Configurations as designed using APCO’s online Design Studio 2 application, to include the following sign types:

NOTE TO SPECIFIER ** Delete options/sign types if not required.

a.EV_ _ -A4 Personnel Sign – Small. (4-1/16” to 5-9/16”)h x 8-1/2”w.

b.EV_ _-B12 Room/Personnel ID. (6-1/8” to 7-5/8”)h x 8-1/2”w.

c.EV_ _-B18 Room ID. (8-1/8” to 8-5/8”)h x 8-1/2”w.

d.EV_ _-R1 Restroom ID. (10-1/8” to 10-5/8”)h x 6”w.

e.EV_ _-C1.R Patient Information. (14-3/16” to 14-11/16”)h x 8-1/2”w.

f.EV_ _-B20 Room ID. (10-7/16” to 11-15/16”)h x 8-1/2”w.

g.EV_ _-F6 Stair ID – Small. (10-7/16” to 11-15/16”)h x 8-1/2”w.

h.EV_ _-F9 Stair ID – Large. (13-1/8” to 13-1/2”)h x 11”w.

i.EV_ _-B28 Room ID – Large. (16-1/4” to 17-3/4”)h x 8-1/2”w.

j.EV_ _-B22 Conference Room ID. (11-11/16” to 13-3/16”)h x 8-1/2”w.

k.EV_ _-R.P1 Overhead Wall Projection. 8-1/2”h x 8-1/2”w.

l.EV_ _-D5 Directional w/ Paper Insert. (22-1/4” to 22-5/8”)h x 11”w.

m.EV_ _-E3 Fire Evacuation. (14-3/4” to 16-5/8”)h x 11”w.

n.EV_ _-B4 Tactile Room ID – Small. (5-5/16” to 7-1/16”)h x 8-1/2”w.

o.EV_ _-D.O1 Overhead Ceiling. 8”h x 36”w.

p.EV_ _-D10 Directional w/ Printed Inserts. (30-1/8” to 31”)h x 17”w.

q.EV_ _-K5 Directory w/ InsertSlots. (23-5/16” to 24-1/16”)h x 14”w.

B.Tamper Proof Feature

NOTE TO SPECIFIER ** Delete options if not required.

1.EV__T: Signs are to use the optional Tamper-Proof feature.

2.EV__: Signs will not use the optional Tamper-Proof feature.

C.Inter-Insert Reveal

NOTE TO SPECIFIER ** Delete options if not required.

1.EV__: Signs are to feature the standard 1/16” inter-insert reveal.

2.EV__-NR: Signs are not to feature any inter-insert reveals.

NOTE TO SPECIFIER ** Delete options if not required.

D.Insert/Display Components to Include:

1.Acrylic Color Band (EV-ACR):

1/8” thick acrylic panel with painted edge/background and direct print graphics. Direct-print graphics options include images from #6 following.

2.Satin Anodized AluminumBand (EV-ALU-NS):

1/8” thick aluminum with a satin anodized finish and brushed edges. Graphics are direct-print.

3.ADA Color Band (EV-341A-DPT):

1/8” thickacrylic with APCO’s DP-Tactile process direct-print, UV-cured, 1/32” thick tactile characters and fully domed Braille.

4.Satin Anodized Aluminum ADA Band (EV-ALU-DPT):

1/8” thick aluminum with a natural satin anodized finish and APCO’s DP-Tactile process direct-print, UV-cured, 1/32” thick tactile characters and fully domed Braille.

5.Decorative Aluminum Divider Bar:

a.(EV-DBL): ¼” x ¼” thick divider with 1/16” inter-insert reveals.

b.(EV-DBL-NR): ¼” x ¼” thick divider with NO inter-insert reveals.

c.(EV-DBS): ¼” x 1/8” thick divider with 1/16” inter-insert reveals.

d.(EV-DBS-NR): ¼” x 1/8” thick divider with NO inter-insert reveals.

6.Aluminum Composite Decorative Image Band (EV-ACM____-IG):

3mm (1/8”) thick aluminum composite with the .012” aluminum face formed precisely around all four edges of the panel to conceal its composite core and a direct-print background image that bleeds around all four edges/returns of the panel. Specify custom imageor select from manufacturer’s standard options:

a.Manufacturer’s Standard Image: EV-ACM______-IG.

b.Custom Image: ______

7.Aluminum InsertSlot (EV-IS):

Extruded aluminum InsertSlot to accept perforated paper inserts with non-glare protective overlays. InsertSlots feature flexible, .020” clear plastic end caps to retain the paper on both sides of the band. Select from the following sizes:

a.1-1/2” h (EV-IS15) by 6”, 8.5”, 11", 14” or 17"w

b.2” h (EV-IS20) by 6”, 8.5”, 11”, 14” or 17"w

c.2.5” h (EV-IS25) by 6”, 8.5”, 11” or 14”w

d.3” h (EV-IS30) by 6”, 8.5”, 11” or 14”w

8.Aluminum Changeable Slide Band (EV-SL):

1-1/2”h aluminum InsertSlot with .020” clear plastic end caps on both sides and a vinyl sliding component. Graphics are direct-print.

9.Acrylic Window (EV-WIN):

Non-glare acrylic lens assembly with a pocket to house a sub-surface, digitally printed insert. For 3"h, 4"h and 6"h inserts, backer is 1/16" thick opaque acrylic. For larger heights, backer is a rigid, 2mm (.080”) aluminum composite panel. For all heights, face is 1/16” non-glare acrylic. Pocket is created withdouble-sided tape at the top and bottom of the window, concealed with a 7/16” subsurface direct-print border. Overall thickness for 3"h, 4"h and 6"h sizes is 5/32". For larger heights, overall thickness is 3/16". Select from the following manufacturer’s standard sizes:

a.(EV-WIN03): 3”h x Standard Width to accept 2-3/8”h Insert

b.(EV-WIN04): 4”h x Standard Width to accept 3-3/8”h Insert

c.(EV-WIN06): 6”h x Standard Width to accept 5-3/8”h Insert

d.(EV-WIN85): 9-1/8”h x Standard Width to accept 8-1/2”h Insert

e.(EV-WIN11): 11-5/8”h x Standard Width to accept 11”h Insert

f.(EV-WIN14): 14-5/8”h x Standard Width to accept 14”h Insert

g.(EV-WIN17): 17-5/8”h x Standard Width to accept 17”h Insert

10.Decorative Shape Header Insert:

a.(EV-DSAC): 1/8” Acrylic – Arc Shape

b.(EV-DSCV): 1/8” Acrylic – Curve Shape

c.(EV-DSSC): 1/8” Acrylic – Scroll Shape

d.(EV-ALU-DSAC): 1/8” Satin Anodized Aluminum – Arc Shape

e.(EV-ALU-DSCV): 1/8” Satin Anodized Aluminum – Curve Shape

f.(EV-ALU-DSSC): 1/8” Satin Anodized Aluminum – Scroll Shape

11.Decorative Shape ADA Header Insert:

a.(EV-341DSAC-DPT): 1/8” Acrylic with Direct-Print Tactile Characters & Braille – Arc Shape

b.(EV-341DSCV-DPT): 1/8” Acrylic with Direct-Print Tactile Characters & Braille – Curve Shape

c.(EV-341DSSC-DPT): 1/8” Acrylic with Direct-Print Tactile Characters & Braille – Scroll Shape