2014 Tri State Ohio Valley Mine Rescue
NMRA Post # 6
Bio-Pak 240 R Written Examination
- Oxygen will ____ cause materials to ______without the presence of an ignitionsource.
always, ignitenot, ignitesometimes, burn
- The BioPak 240 Revolution is approved when the oxygen cylinder is fullycharged with compressed ______or aviation grade oxygen at _____ psi.
construction, 3010medical, 2660medical, 3000
- Always ______for a current ______test date.
look, manufacturerscheck, hydrostaticcheck, manufacturers
- Replace the battery when the low battery alarm has activated, after ______ofuse or every 6 months whichever comes first.
100, hours200, days200, hours
- The usual scrubber consists of ______and a ______core. Do not reusepreviously used CO2 absorbent cartridges or the rubber gaskets.
pumice, paperlimestone, paperlimestone, plastic
- Allow all components to remain ______by the cleaning solution a minimum of 10 minutes.
wettedmoistsoaked
- Apply anti-fog solution or _____ to both halves of the ______before every useto ensure mask lens do not scratch.
water, feltwater, chamoissoap, chamois
- Do not expose opened CO2 scrubber cartridges to ______air for more than 20minutes.
outsidedryambient
- Install each CO2 canister into the SCBA so that the ____ end cap is ______on thetop side of the canister.
red, lookingblue, visiblered, visible
- A low battery alarm is indicated by a Red, Green, Blue light sequence followedby a _____ alarm _____ any time the battery will not complete a four-hour mission.
momentary, beepshort, beepshort, chirp
- If a quick Turn-Around ______has been performed, the SCBA will functionand is designed to work wet.
CleaningMaintenanceTesting
- The RMS will automatically ______once the system pressure has droppedbelow 25 psig.
power, downturn, offpower, up
- ______-____ and Dow-111 are the only o-ring lubricants that shall be utilized onthe SCBA components.
Cristo-GreaseSilicone-LubeCristo-Lube
- ______Use Dow 111 on any o-ring seal that comes in contact with high-pressure
oxygen.
ALWAYSNEVERSOMETIMES
- High breathing ______during ______could be caused by the facepieceexhalation valve sticking closed.
rates, inhalationrates, exhalationresistance, exhalation
- High breathing resistance during inhalation could be caused by the facepiece______check valve sticking closed.
inhalationexhalationbreathing
- High breathing ______during ______could be caused by the demandvalve in breathing chamber has failed.
resistance, exhalationresistance, inhalationrates, breathing
- BioPak weight, ready to use is 34 pounds.
433436
- BioPak Carbon Dioxide Scrubber is Dual, single use ______cartridges, non-dusting, non-channeling, non-hazardous.
Limestone PelletsCalcium HydroxideCalcium Pellets
- The CO2 Scrubber should be replaced after ___ use.
everymultiple1
Tri State Ohio Valley Mine Rescue Contest
Bio-Pak 240 R
Identification of Parts Test of the Written Exam
2014 Tri State Ohio Valley Mine Rescue
NMRA Post # 6
Bio-Pak 240 R Written Examination
ANSWERS
- Oxygen will ____ cause materials to ______without the presence of an ignitionsource.
always, ignitenot, ignitesometimes, burn(SF #9)
- The BioPak 240 Revolution is approved when the oxygen cylinder is fullycharged with compressed ______or aviation grade oxygen at _____ psi.
construction, 3010medical, 2660medical, 3000(SF # 12)
- Always ______for a current ______test date.
look, manufacturerscheck, hydrostaticcheck, manufacturers(SF # 15)
- Replace the battery when the low battery alarm has activated, after ______ofuse or every 6 months whichever comes first.
100, hours200, days200, hours(SF # 20)
- The usual scrubber consists of ______and a ______core. Do not reusepreviously used CO2 absorbent cartridges or the rubber gaskets.
pumice, paperlimestone, paperlimestone, plastic(SF # 25)
- Allow all components to remain ______by the cleaning solution a minimum of 10 minutes.
wettedmoistsoaked(SF # 31)
- Apply anti-fog solution or _____ to both halves of the ______before every useto ensure mask lens do not scratch.
water, feltwater, chamoissoap, chamois(SF # 35)
- Do not expose opened CO2 scrubber cartridges to ______air for more than 20minutes.
outsidedryambient(SF # 39)
- Install each CO2 canister into the SCBA so that the ____ end cap is ______on thetop side of the canister.
red, lookingblue, visiblered, visible(SF # 41)
- A low battery alarm is indicated by a Red, Green, Blue light sequence followed by a _____ alarm _____ any time the battery will not complete a four-hour mission.
momentary, beepshort, beepshort, chirp(SF # 47)
- If a quick Turn-Around ______has been performed, the SCBA will functionand is designed to work wet.
CleaningMaintenanceTesting(SF # 51)
- The RMS will automatically ______once the system pressure has droppedbelow 25 psig.
power, downturn, offpower, up(SF # 54)
- ______-____ and Dow-111 are the only o-ring lubricants that shall be utilized onthe SCBA components.
Cristo-GreaseSilicone-LubeCristo-Lube(SF # 56)
- ______Use Dow 111 on any o-ring seal that comes in contact with high-pressure
oxygen.
ALWAYSNEVERSOMETIMES(SF # 57)
- High breathing ______during ______could be caused by the facepieceexhalation valve sticking closed.
rates, inhalationrates, exhalationresistance, exhalation(SF 68)
- High breathing resistance during inhalation could be caused by the facepiece ______check valve sticking closed.
inhalationexhalationbreathing(SF # 71)
- High breathing ______during ______could be caused by the demandvalve in breathing chamber has failed.
resistance, exhalationresistance, inhalationrates, breathing(SF73)
- BioPak weight, ready to use is 34 pounds.
433436(SF # 76)
- BioPak Carbon Dioxide Scrubber is Dual, single use ______cartridges, non-dusting, non-channeling, non-hazardous.
Limestone PelletsCalcium HydroxideCalcium Pellets(SF # 78)
- The CO2 Scrubber should be replaced after ___ use.
everymultiple1(SF # 85)
Tri State Ohio Valley Mine Rescue Contest
Bio-Pak 240 R
Identification of Parts Test of the Written Exam