/ LAFON’sreference: 18295050 / EASY CARB Terminal
International Instruction Book
xx/yy/2009 / Date: 05/2009
version E

EASY CARB TERMINAL

18 29 53 00 Release (International version)

  • Installation Instruction
  • User’sManual
  • Maintenance Book

BEFORE ANY USE OR INTERVENTION ON ANY PART DEPENDING OF ATEX DIRECTIVE (guideline), READ ATTENTIVLY THE SECURITY INSTRUCTION LEAFLET.

Update History Table

Version / Pages Changed / Nature of change / Date(Day/M/Year)
A / CREATION / 13/04/2008
B / Global Modification / 09/09/2008
C / 1; 8; 9; 16; 32 / RFID Integration / 16/01/2009

1)CONTENTS

Summary

)) Update History Table

1)CONTENTS

2)Generalities

3)Technicals specificities

4)Rules and status / regulation ( ??? norme de règlementation)

5)Kit Content / Kit composition.

8)Power protection

10)Overview map, nomenclature (part list) and spare part.

a)EasyC@rb Terminal.

11)Encumbrance (or Space encumbrance)

12)Installation

a)Mounting the fixing clamp, B-type: the small one.

b)Fitting the extra whistand one.

13)Maintenance procedure rules

14)Leaflet utilization’s electronic card

a)Power supply and Network Links: Generalities

b)Rs485 Local Network cabling rules

c)Typical Examples of wiring an rs485 network interfaced with our equipments

15)The Display

16)Identification Mains

17)Terminal function configuration: “Terminal Config”

a)Functioning mode configuration

b)Rs485 Local Network

c)Default Ethernet Network configuration process

d)AbiPass nozzles configuration

18)Fuel function configuration

a.Dispensing Mode

b.Counting channel

c.Functioning

d.Pulse Weight

e.Gauging

19)Functioning check

a.The power supply

b.Backlighting display

c.The Keyboard / Keypad

d.Everlasting (perpetual, perennial) totalizer(s)

e.The identification (ID)

f.The printer (option)

g.The fuel dispensing

h.Error list table

20)Software downloading

a.Downloading by communication protocol

b.Downloading by EuroGestion programmer (scheduler)

21)“Synoptical” Cabling pattern (chart)

22)EasyCarb interfacing with CMP

23)EasyCarb interfacing with a MicroBasic Card

24)Annexes (Attachments)

a.Synoptical of Terminal configuration menu

b.Synoptical of Fuel configuration menu

25)Spare parts list

2)Generalities

The E@syCarb terminal is a private fleet management system connected to the EasyConnect software. It allows to access at(to) a fuel dispensing (3 product maximum) a vehicle or/and a person. It regroups in one device the site controller functions, the HMI interface (terminal)and product counting(metering). EasyC@rb is principally intented to basic architecture site (managing a single dispenser). Hence there is no rs485 local network to deploy.

Even so, for the more important(“meaty”) site where the usage, for example, who requires the addition of terminal, calculator or the both. In consequence,the cabling in Rs485 protocol is necessary in.

The EasyCarb Terminal manages a LCD screen divided in 2 separates zone.

The upper display zone is used for the refueling (volume display, product, and nozzle)

The lower display zone is constituted with 4 lines, 20 digits each. It’s used for managing authorization.

The EasyC@rb terminal has got a 21 Alfa numeric keyboard (cell-phone type) with 21 keys.

The EasyC@rb allows to:

  • Identify a person with the following means:
  • Alfa numeric keypad (cellular phone type) of 21 keys.
  • Lafon badges
  • Abipass Lafon antenna
  • ISO2 Magnetic card
  • RFID badges (contactless)
  • ISO 7816 Smart card
  • After identification, an authorization can be issued or denied for a refueling.

The EasyC@rb license can’t manage access or washing. For this features an add-on license is necessary.

3)Technicals specificities

Power supply / 230 VAC – 50 Hz / 60Hz
3 Pulsers entries / A 63 mA temporized fuse
Electrical protection / 1 or 2 channel. 5V power supply
3 Nozzle entries / Dry contact (lift closed contact)
Pulse Maximal frequency / 500 Hz (Hertz)
3 Engine (motor) command. VAC 230 by static relay supplied. / 1A max (resistive load
Pulse weight / Adjusting from 0.000001 to 0.999999 L (Liters)
Perpetual Totalizer counting channel / 00000000 to 99999999 L (Liters)
Displayed volume / From 0.01 to 999999 L (Liters)
Using temperature limitation / Celsius: from -10°C to + 50°C

!Disclaimer !

Every kind of non-respect of this present technical instruction disclaimsany responsibility and any liability in(to) LAFON Company.

4)Rules and status / regulation ( ??? norme de règlementation)

The EasyC@rb terminal is approved to the following European legislation. It respects the laws in force below.

  • Low Tension directive 72/*23/CEE modified by the 93/68/CEE (CE mark)
  • The Electricals Low tension installation rules: NFC15-100
  • The 94/62/CE: packaging and packaging wastage

5)Kit Content /Kit composition.

The containing kit:

  • 1 EasyC@rb terminal part number: 1 82 95 30 0
  • 1 spare-part fuse
  • 3 fixation devices binding
  • The cutting template (( cutting pattern/ layout)
  • This notice instruction (this technical notice / this instructions note / this instruction manual)

6)Place to install each (every) parts / devices.------

All the items of this kit, must be assembled any outside ATEX area.

7)People Safety / Save ------

Do not power connection.((or (Don’t make any connection (plugs) in tension)))

Please, be sure to follow the instructions for the safety persons.

8)Power protection

Power supply features (specificities):

  • Power supply tension 230V AC 50 Hz—A 230 V AC 50Hz Tension power supplied.
  • Protection by a built-in 63 mA fuse temporized on the EasyC@rb electronic card(circuit).

The system must be protected against

  • The shorts (circuits)
  • The overload(s)

An upstream(en amont) protection of the Electronic(circuit)card breaker(circuit-breaker) is recommended by.

The installation and protection mode must be true to the NFC 15-100.------

9)People Safety(protection)------

Insurethe people safety by connecting with the bounding strip (reference 18280620) between the terminal framework metal sheet (1829503) and the EasyC@rb device framework.

Check the connections from the ground to the metallic part.

Verify (keep tabs on) if the device(dispositive) is really protected by a differential“circuit breaker”with a caliber which it must be in accordance with(doit être conforme) the NFC- 15-100.

10)Overview map, nomenclature (part list) and spare part.

The maintenancemust be imperatively made with the manufacturer’s original equipment

to respect the regulatory requirements related to the product (item). Use only genuine part

LAFON S.A Company no longer has any liability if this requirement is not complied with.

a)EasyC@rb Terminal.

N° / Reference / Type / Qty / Descritpion / Description 2
1 / 18295230 / S/E / 1 / EasyC@rb metal sheet
2 / 18295000 / S/E / 1 / EasyC@rb electronic cpu card
3 / 00032046 / 1
4 / 00930073 / 1 / 4 INOX
5 / 18295080 / S/E / 4 / Low-cost Enhanced Display
6 / 18295200 / 1
7 / 18295220 / 1
8 / 18295210 / 1 / Easy Keyboard
9 / 00929196 / 10 / 3
10 / 00392003 / 5 / INOX
11 / 00032020 / 4 / Bounding strip
12 / 04709160 / 2
13 / 04709161 / 1
14 / 18295290 / 2 / Easy Terminal Linking Sticker / EASY CARB
15 / 18295310 / 1
16 / 18295320 / 1
17 / 01609044 / 1
18 / 01229000 / 1
19 / 18280620 / 1 / 500mm Qualys Ground
20 / 18294040 / 1 m
21 / 18295050 / 1 mL / Installer/ Maintainer Notice / Easy Carb Terminal

11)Encumbrance (or Space encumbrance)

12)Installation

a)Mounting the fixingclamp, B-type: the small one.

Once the EasyC@rb device clipped inside the dispenser head framework.Bottom side, from the back fix and mount the terminal clamping part.

Snap the fixing clamp on the both screw head. Apply a fitting clamping with an appropriate size screwdriver.

Don’t tighten with any clamp (or: don’t use with any clamping clamps).

b)Fitting the extra whistand one.

In the same way, after snapping the 2 clamp part onto own each screw-head, with an acceptable screwdriver size, turn and apply an appropriate clamping.

DON’ T USE WITH CLAMPING FORCEPS

(traduction française: Ne pas utiliser de serrage avec une pince)

13)Maintenance procedure rules

To prevent any damage that might result in electric shock or fire. Disconnect the Main power prior to any up keeping work.

Any kind of intervention on the electric part must be done by an approved technician.

14)Leaflet utilization’s electronic card

a)Power supply and Network Links: Generalities

High Voltage. The EasyC@rb card is supplied with 230V AC.

If the EasyC@rb card required to be connected on the Rs485 network with a STP cable we recommend using this one:

Rs485 cable reference: BELDEN 1 Shielded Twisted-Pair (0.22 mm² section).
With drain. Part Number:B9841.

b)Rs485 Local Network cabling rules

Here below the rs485 typology. It’s also the only way to connect any devices on it and to make it properly.

EasyC@rb device is of 2 Rs485 connectors.

Bus type:

Note: The EasyC@rb Terminal is equipped with a single rs485 connector.

(3 wires, 3 channels from up to down: C, B, and A)

Warning:It’s strictly forbidden to cable, to make an RS485 network wiring star:

c)Typical Examples of wiring an rs485 network interfaced with our equipments

(products, “Easy” Range devices) (( or rs485 network where it’s connected our equipment using Cases

Rs485 Network Casesused to with our equipments.)))

The Rs485 3 wires connection from the first to the last card respects this following links:

  1. A to A
  2. B to B
  3. C to C (cable shielding)

On the Rs485 network,each (1 and 2 on the scheme) ENDPOINT’s resistors terminations must be necessary switched on. The 2 switches are activated to eliminate any kind of reflection line. (See the Establishment Map).

15)The Display

The EasyC@rb Cardhas 2 pin connectors which can drive 2 black-lighted display panels of 128*64 dots each.

Their displayed data are strictly the same. So, it allows makingfor(give, assure) the recopy feature.

Or: As the transmitted data from each connector are the same. It enables to ensure the recopy feature

On each display, 2 specific areas have been created.

Upper zone: Numerical information data. This area displays data related to Volume, summarizing (total) and error during refueling.

Lower zone: 4 lines. This area is reserved to inform the user about the site management.

It displays: Names, wording, date/hours, identification, messages, and device configuration

“”The characters height used to display volume allows visualizing the volume data to more than a 4 meter distance at least

Or

The digit height used to display the volume allows to clearly visualizing information at a range up to 4 meter at least

For notice needs, the 4 select keys are associated to each line EasyC@rb terminal’s display. In consequence from up to down:

/ = F1 key
= F2 key
= F3 key
= F4 key

The and keys allowto navigate into both mode setting terminal.

16)Identification Mains

Identification Type / Device support / Mark on Sticker
Secret code and name Keyboard / Keyboard / Keyboard dab
EASY, GLS, Connection and Stand-alone Abiself, Badge / Badge Lafon / Badge reader
Abipass / Abipass antenna / ISO 2 or Abipass antenna
ISO 2 / Magnetic card reader
(ISO2 track only) / ISO 2 or Abipass antenna
Smart-card reader (ISO 7816) / Smart-card
RFID Contactless / Contactless badge / ISO 2 or Abipass antenna

Below the card’s mapping (identification of the EasyC@rb card) with its various buttons and switches.

17)Terminal function configuration: “Terminal Config”

Important point

To enterintothe terminal configuration menu,visualizethe current setting, test identifications devices plugged to EasyC@rb, and change the default IP setting, just press simultaneously the both following keyboardkeys:▲ (up arrow key) and ●(dot key). Thereafter, the user has to type the 4 digit key-code.By default it’s0557.

In this way, you can access to the Terminal Config Menu for checking and edit some features.

a)Functioning mode configuration

The EasyC@rb card manages only the fuel terminal function. The others features, Access and Washing, are not available.

b)Rs485 Local Network

On the Rs485 network, the EasyC@rb card does not require any addressing network configuration for working with every Easy range devices.

c)Default Ethernet Network configuration process

The default IP stored is: 192.168.1.87

This feature is included into the EasyC@rb Configuration Menu. Itenables to set (to map) EasyC@rbIP default connection mode into the customerlocal network.

How to access it:

1. See “Important point” chapter 17.

2. Go to “Terminal Config”Default Ip ConfigEdit Config

Type all required values: Ip, Mask, Gate and / or Port

Type V keyA key V: yes (Save your current typing) A key A to reset the Terminal with the correct values.

See Treediagram EasyC@rb configuration Menu page xxxx.

How to use it:

  1. Press the ACQ button (press-stud) into the EasyC@rb card.
  2. Wait the L2 led lights-up. Red color
  3. Relate to the EasyConnect Help to download the xml file into easyc@rb.

The

d)AbiPass nozzles configuration

If the ABIPASS system (Automatic identification system)fits up (equips) the site, the fueling terminal has to establish the communication bridge between the nozzle number ID (as satellite) and the “master” dispenser.

Note:

This operation could be done only if the fuel terminal has been configured by the maintainer through the maintenance mode (EasyC@rb card)

Maintenance mode (Seeon Important point§ 17) Terminal Config MenuAbipass

If this feature is normally configured the user should be seeing:

LAFON test site
16/09/2009 15:52:49
Identify Driver

Note:All the following messages:

“OUT OF SERVICE: LANGAGE” or “OUT OF SERVICE: CONFIG”or“SATELLITESLAVE ADRESS OUT of SERVICE”…,

Indicate that the Terminal is not able to receive any kind of wrights setting from the site controller.

In this case, please check the site controller ABIPASS setting.

Terminal DISPLAY / INSTALLER ACTION
LAFON Test site
16/02/2009 15:52:49
Indentify driver
/ To go into EasyC@rb system test configuration Menu. Push the Config installer press-stud (see the back framework sticker).
Terminal Config
Fuel Config
/ Press F1 key to select the Terminal function configuration
Abipass Config
Identification
Printer
Default ip config
/ Press F1 keyto selectAbipass Config
Dispenser 01
Dispenser 02
Dispenser 03
/ The dispenser list or the dispenser displays on.
Press F3 key to configure the dispenser N°3
Dispenser 03
Nozzle GO
Nozzle 1: 0000
Nozzle 2: 0000
/ It can be possible (potential) to configure 2 physical ABIPASS nozzles for 1 logical nozzle (Gasoil Nozzle).
I.E.: In the case of Satellite nozzle.The “ ” cursor shows the Abipass nozzle to configure. Unhook the kitted (manned) warden (custody) Abipass nozzle.
Overbalance the nozzle during 3 seconds like as you put it into a tank and hang-up it to display the Number nozzle onto the EasyC@rb display.
Dispenser : 03
GO nozzle
Nozzle 1: 0504
Nozzle 2: 0000
/ “Nozzle 1” normally displays. If there is another one to configure, press the Up and Down arrows keys to move the cursor face to “Nozzle 2” line or just press V key to validate this choice.
Dispenser : 01
Dispenser : 02
Dispenser : 03
/ This message displays, so press A key if there is no more Abipass nozzles to set-up
Abipass Config
Saving
A: No V:Yes
/ At this step,Press the V key to save the Abipass setting (inside the EasyC@rb system memory.)

Next page: ABIPASS nozzle configuration procedure, I.E.: linked to the 3rd Dispenser.

18) Fuel function configuration

The refueling feature can be tested irrespective of(independently from) the management connected mode function). Duly (like this, that way) the installer could configure the fuel function and makes some checking with autonomous manner.

Important Notes (Key-Point): Config Fuel Menu

First of all, the configuration modification of the Fuel Terminalsetting is carried out bypressing the “Config Installer” press-stud. However, it’s recommended to open the dispenser head door for handling and access to the EasyC@rb card.

To configure this mode (Config Fuel Menu), use the arrows keys and the keypad to adjust the settings.

OR

To modify the configuration

On the EasyCarb card lower area left side, push the “CONF” button

To check the configuration and change only the IP feature:

Press the arrows key and type the secret code (by default 0557)

Table Reminder

Configuration menus on the EasyCarb display / Access mode / Where and how to push / Viewing / Editing
Config Terminal / Key combination / 2 Arrows keys and keypad secret code / Yes / IP setting only
Fuel Config / “CONFIG”
Press-stud / On the EasyCarb card.
Left side lower area. / Yes / All the features

The synoptic’s configuration menu of fuel is given in annex.

  1. Dispensing Mode

There are 2 separate functioning modes for fuel dispensers :

  • Non-simultaneous Mode
  • Simultaneous Mode

The Non-Simultaneous mode:

It’s defines with 1F 1P, 1F 2P or1F 3P signs which signify 1 Face 1 Nozzle,1 Face 2 Nozzles or 1 Face 3 Nozzles. When To the lifted Nozzle, the delivery (dispensing) starts. Only 1 product is distributed (delivered, fueled, dispensed) at the same time.

The Simultaneous mode:

It’s defines with CS 1P, CS 2P or CS 3P signs who signify Simultaneous Counting 1 Nozzle, Simultaneous Counting 2 Nozzles, or Simultaneous Counting 3 Nozzles.From each lifted nozzle afilling is initialized. The dispensed volume amount who aredisplayed, is a single one

The amount volume who displays inside the upper area display totalizes all the last transactions from each lifted nozzles. It displays them to a loop slideshow every 2 seconds.

Or

The amount volume who displays in the upper area display totalizes all the last transactions from each lifted nozzles. it displays them to a loop slideshow every 2 seconds.

(The volume's amount displayed and dispensed is a single one.)

Respectively the channel A is for the first nozzle, B for the second and C for the third.

Note:

For a single nozzle, theses both functioning modes (1F 1P and CS 1P) are nearly the same.

  1. Counting channel

For each pulse entries, it can be possible to determinate the number of counting (metering) voices.

To each pulse entry, it can be to define the number of counting channel (1 or 2). In fact … . In the case where only 1counting (metering) channel is configured. The disconnection control system of the counting (metering) voice of the calculator is disabled.

Example: Process to define1 single counting entry from the dispenser number 3.

Terminal DISPLAY / INSTALLER ACTION
/ In order to modify the EasyC@rb’ system configuration, press the Config Installerpushbutton (See sticker)
/ So as to select the Wright function configuration,
Press the F2 Key to configure the Config Fuel function.
/ Press F2 Key to select the pulse channel
/ The dispensers list displays on.
Press the F3 key in order to customize the 3rd dispenser.
/ Press the C key to correct the pulse channel number.
/ Then, the display shows …
Just press V key to validate your choice or C key to correct one.
/ After validation, the cursor back to the previous menu.
To quit (close) this configuration menu, press A key to return (go back, into) (get back) the main menu.
Terminal DISPLAY / INSTALLER ACTION
/ You have to press the A key again to restart the device. The system (and the card) will reboot automatically.
/ Before to perform a complete reboot, this following screen proposes to the user, to save the modified setting or to reboot without any modification.
  1. Functioning

This calculator (device) could be sets up to a Stand-Alone or a Connected Mode.